M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
12Program Errors (P)
These alarms occur during automatic operation‚ and the causes of these alarms are mainly program errors which
occur‚ for instance‚ when mistakes have been made in the preparation of the machining programs or when programs
which conform to the specification have not been prepared.
P10
No. of simultaneous axes over
Details
The number of axis addresses commanded in a block is exceeds the specifications.
Remedy
Divide the alarm block command into two.
Check the specifications.
P11
Illegal axis address
Details
The axis address commanded by the program does not match any of the ones set by the parameter.
Remedy
Correct the axis names in the program.
P20
Division error
Details
The issued axis command cannot be divided by the command unit.
A cutting feed command has been issued to the index table indexing axis when the parameter "#2580 in-
dex_ Gcmd" is set to "1".
Remedy
Correct the program.
P29
Not accept command
Details
The command has been issued when it is impossible.
The normal line control command (G40.1, G41.1, G42.1) has been issued during the modal in which the
normal line control is not acceptable.
The command has been issued during the modal in which the 2-part system synchronous thread cutting
is not acceptable.
A workpiece coordinate system preset command (G92.1) has been issued during tool length compensa-
tion, nose R compensation or tool radius compensation.
Remedy
Correct the program.
P30
Parity H error
Details
The number of holes per character on the paper tape is even for EIA code and odd for ISO code.
Remedy
Check the paper tape.
Check the tape puncher and tape reader.
P31
Parity V error
Details
The number of characters per block on the paper tape is odd.
Remedy
Make the number of characters per block on the paper tape even.
Set the parameter parity V selection OFF.
IB-1501279-H
124