No. Of Simultaneous Axes Over; Illegal Axis Address; Division Error; Not Accept Command - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
12Program Errors (P)
These alarms occur during automatic operation‚ and the causes of these alarms are mainly program errors which
occur‚ for instance‚ when mistakes have been made in the preparation of the machining programs or when programs
which conform to the specification have not been prepared.
P10

No. of simultaneous axes over

Details
The number of axis addresses commanded in a block is exceeds the specifications.
Remedy
Divide the alarm block command into two.
Check the specifications.
P11

Illegal axis address

Details
The axis address commanded by the program does not match any of the ones set by the parameter.
Remedy
Correct the axis names in the program.
P20

Division error

Details
The issued axis command cannot be divided by the command unit.
A cutting feed command has been issued to the index table indexing axis when the parameter "#2580 in-
dex_ Gcmd" is set to "1".
Remedy
Correct the program.
P29

Not accept command

Details
The command has been issued when it is impossible.
The normal line control command (G40.1, G41.1, G42.1) has been issued during the modal in which the
normal line control is not acceptable.
The command has been issued during the modal in which the 2-part system synchronous thread cutting
is not acceptable.
A workpiece coordinate system preset command (G92.1) has been issued during tool length compensa-
tion, nose R compensation or tool radius compensation.
Remedy
Correct the program.
P30
Parity H error
Details
The number of holes per character on the paper tape is even for EIA code and odd for ISO code.
Remedy
Check the paper tape.
Check the tape puncher and tape reader.
P31
Parity V error
Details
The number of characters per block on the paper tape is odd.
Remedy
Make the number of characters per block on the paper tape even.
Set the parameter parity V selection OFF.
IB-1501279-H
124

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents