M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1339
MC_dp3
When safety observation is executed, set the remote I/O device to input the contactor's auxiliary b contact
signal used for the contactor weld detection.
If "0" is set, weld detection will not be executed.
Thus, "X0" cannot be used as contactor weld detection device.
---Setting range---
[M8]
000 to 02FF (HEX)
[C80]
0000 to 01FF (HEX)
(PR)
#1340
MC_dp4
When safety observation is executed, set the remote I/O device to input the contactor's auxiliary b contact
signal used for the contactor weld detection.
If "0" is set, weld detection will not be executed.
Thus, "X0" cannot be used as contactor weld detection device.
---Setting range---
[M8]
000 to 02FF (HEX)
[C80]
0000 to 01FF (HEX)
#1342
AlmDly
Set a period of time by which alarm display is delayed.
Set a time between when an operation alarm occurs and when the alarm display and signal turn ON.
When set to "0", the alarm display and signal will turn ON immediately after the alarm occurrence.
When set to "-1", the alarm display and signal will not turn ON after the alarm occurrence.
Target alarms:
M01 External interlock axis found 0004
M01 Internal interlock axis found 0005
M01 Sensor signal illegal ON 0019
M01 No operation mode 0101
This parameter is disabled if "#1343 DlyReg" is set.
---Setting range---
-1 to 30000 (ms)
(PR)
#1343
DlyReg
Set the head No. of the R register to be used for delayed display of an operation alarm.
If any R register outside the user area is specified, delayed alarm display is disabled.
If this parameter is set, the setting of #1342 AlmDly is disabled. When not using, set to "0".
---Setting range---
0 to 29899
(PR)
#1349
DOOR_1
Set a remote I/O device to input the door sensor signal to detect Door 1's status in safety observation.
When "0" is set, the door is always detected to be open.
Thus, "X0" cannot be used as Door 1 switch input device.
---Setting range---
0000 to 02FF (HEX)
(PR)
#1350
DOOR_2
Set a remote I/O device to input the door sensor signal to detect Door 2's status in safety observation.
When "0" is set, the door is always detected to be open.
Thus, "X0" cannot be used as Door 2 switch input device.
---Setting range---
0000 to 02FF (HEX)
Contactor weld detection device 3
Contactor weld detection device 4
Alarm display delay time
R register for delayed alarm display setting
Door 1 switch input device
Door 2 switch input device
437