M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#1030
aux_J
Set the axis name when there is an axis parallel to "#1027 base_J".
---Setting range---
Axis names such as X, Y or Z
#1031
aux_K
Set the axis name when there is an axis parallel to "#1028 base_K".
---Setting range---
Axis names such as X, Y or Z
#1084
RadErr
Set the tolerable error range when the end point deviates from the center coordinate in the circular command.
---Setting range---
0 to 1.000 (mm)
#1171
taprov
Set the tap return override value for the synchronous tapping.
When "0" is set, it will be regarded as 100%.
---Setting range---
0 to 100 (%)
#1185
spd_F1
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F1 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be increased/de-
creased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
#1186
spd_F2
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F2 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be increased/de-
creased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
#1187
spd_F3
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F3 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be increased/de-
creased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
Flat axis J
Flat axis K
Arc error
Tap return override
F1 digit feedrate F1
F1 digit feedrate F2
F1 digit feedrate F3
203
IB-1501279-H