16 Machine Parameters
#3053
sppst
Set the deviation amount from the spindle's basic point to the spindle encoder's Z phase.
Obtain the deviation amount, considering a clockwise direction as positive when viewed from the spindle's
front side.
---Setting range---
0 to 359999 (1/1000°)
#3054
sptc1
Set the speed which switches from 1st step to 2nd step in spindle synchronization multi-step acceleration/
deceleration control. Set the same value for the reference axis and synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
#3055
sptc2
Set the speed which switches from 2nd step to 3rd step in spindle synchronization multi-step acceleration/
deceleration control. Set the same value for the reference axis and synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
#3056
sptc3
Set the speed which switches from 3rd step to 4th step in spindle synchronization multi-step acceleration/
deceleration control. Set the same value for the reference axis and synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
#3057
sptc4
Set the speed which switches from 4th step to 5th step in spindle synchronization multi-step acceleration/
deceleration control. Set the same value for the reference axis and synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
#3058
sptc5
Set the speed which switches from 5th step to 6th step in spindle synchronization multi-step acceleration/
deceleration control. Set the same value for the reference axis and synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
#3059
sptc6
Set the speed which switches from 6th step to 7th step in spindle synchronization multi-step acceleration/
deceleration control. Set the same value for the reference axis and synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
IB-1501279-H
Spindle encoder Z -phase position
Spindle synchronization multi-step acceleration/decel-
eration changeover speed 1
Spindle synchronization multi-step acceleration/decel-
eration changeover speed 2
Spindle synchronization multi-step acceleration/decel-
eration changeover speed 3
Spindle synchronization multi-step acceleration/decel-
eration changeover speed 4
Spindle synchronization multi-step acceleration/decel-
eration changeover speed 5
Spindle synchronization multi-step acceleration/decel-
eration changeover speed 6