M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#11018

M password hold

When set to "1", the "Machine user" (operation level 6) password will be held even if the NC is restarted.
0: Do not hold
1: Machine user password is held
(PR)
#11019

2-system display

Select whether to enable simultaneous display of multiple part systems on the monitor screen.
0: Display one part system on the monitor screen.
1, 2: Display two part systems simultaneously on the monitor screen.
3: Display three part systems simultaneously on the monitor screen.
Note that this is enabled for a 15- or 19-type display unit only. [M8]
4: Display four part systems simultaneously on the monitor screen.
Note that this is enabled for a 15- or 19-type display unit only. [M8]
(Note 1) If the number of part systems to display is smaller than that of the simultaneous display, a single
part system display is selected.
(Note 2) If you select "3" or "4" for any display unit other than 15- or 19-type, a single part system display is
selected.
#11021

PLC mesg disp type

Select the format of PLC alarms and operator messages to be displayed on the bottom right of the screen.
0: Display up to the first 40 characters.
1: If text is longer than 40 characters, divide it into two and display separately. (Supplementary information
is displayed together)
#11022
SRAM Output Type
Not used. Set to "0".
#11023
G33.n Drn
Not used. Set to "0".
#11024
G33.n fhd
Not used. Set to "0".
#11028

Tolerance Arc Cent

Set the tolerable correction value for the calculated coordinate value error of R-specified circular center.
When a difference between "a line between the start and end points" and "commanded radius x 2" is the tol-
erance or smaller, the error is corrected so that the middle of a line between the start and end points will be
the arc center.
When [Setting value < 0] : 0 (Not correct)
When [Setting value = 0] : 2 x minimum setting increment
When [Setting value > 0] : Setting value
---Setting range---
<Metric system> -1 to 0.100 (mm)
<Inch system> -0.0393 to 0.0039 (inch)
#11029
Arc to G1 no Cent
When arc center or radius designation is omitted from arc command, change the arc command into linear
without causing program error.
0: Program error
1: Change into linear command
Machine user password is held
2-part system simultaneous display
Format of PLC alarm and operator message
Tolerable correction value of arc center error
Change command from arc to linear when no arc center
designation