M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#2019
revnum
Set the steps required for reference position return for each axis.
0: Not execute reference position return.
1 to max. number of NC axes: Steps required for reference position return
#2020
o_chkp
Set the distance from the second reference position to the position for checking that the spindle orientation
has completed during second reference position return.
When the set value is "0", the above check will be omitted.
---Setting range---
0 to 99999.999 (mm)
#2021
out_f
Set the maximum speed outside the soft limit range.
---Setting range---
0 to 1000000 (mm/min)
#2022
G30SLX
Select whether to disable a soft limit check during the second to the fourth reference position return in both
automatic and manual operation modes.
0: Enable
1: Disable
#2023
ozfmin
Set the minimum speed outside the soft limit range during the second to the fourth reference position return.
---Setting range---
0 to 1000000 (mm/min)
#2024
synerr
Set the maximum synchronization error, allowable at the synchronization error check, for the master axis.
When "0" is set, the error check will not be carried out.
---Setting range---
0 to 99999.999 (mm)
During simple C-axis synchronous control: 0 to 99999.999(°)
#2061
OT_1B-
Set the coordinate of the lower limit of the area where the stored stroke limit IB is inhibited.
Set a value from zero point in the basic machine coordinate system.
If the same value (non-zero) with the same sign as that of "#2062 OT_IB+" is set, the stored stroke limit IB
function will be disabled.
---Setting range---
-99999.999 to 99999.999 (mm)
#2062
OT_1B+
Set the coordinate of the upper limit of the area where the stored stroke limit IB is inhibited.
Set a value from zero point in the basic machine coordinate system.
---Setting range---
-99999.999 to 99999.999 (mm)
#2063
OT_1B type
Select the type that applies the settings of "#2062 OT_IB+" and "#2061 OT_IB-" in stored stroke limit I.
0: Soft limit IB
1: The settings are invalid
2: Soft limit IC
3: Soft limit is checked for the inclined axis control axis with the program coordinate system.
(Note) This is valid only for inclined axis' base axis and inclined axis.
IB-1501279-H
Return steps
Spindle orientation completion check during second
reference position return
Maximum speed outside soft limit range (For L system
only)
Validate soft limit (automatic and manual)
Set up ATC speed lower limit
Allowable error
Soft limit IB-
Soft limit IB+
Soft limit IB type