Illegal Address; Format Error; Illegal G Code; Setting Value Range Over - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P32

Illegal address

Details
An address not listed in the specifications has been used.
Remedy
Correct the program address.
Correct the parameter settings.
Check the specifications.
P33

Format error

Details
The command format in the program is not correct.
Remedy
Correct the program.
P34

Illegal G code

Details
The commanded G code is not in the specifications.
An illegal G code was commanded during the coordinate rotation command.
G51.2 or G50.2 was commanded when the rotary tool axis No. (the parameter "#1501polyax") was set to
"0".
G51.2 or G50.2 was commanded when the tool axis was set to the linear axis (the parameter "#1017 rot"
= 0).
Remedy
Check and correct the G code address in the program.
Check the parameter setting values.
P35

Setting value range over

Details
The setting range for the addresses has been exceeded.
Remedy
Correct the program.
P36
Program end error
Details
"EOR" has been read during tape and memory mode.
Remedy
Enter the M02 and M30 command at the end of the program.
Enter the M99 command at the end of the subprogram.
P37
O, N number zero
Details
"0" has been specified for program or sequence No.
Remedy
Designate program Nos. within a range from 1 to 99999999.
Designate sequence Nos. within a range from 1 to 99999999.
P38
No spec: Add. Op block skip
Details
"/n" has been issued while the optional block skip addition is not in the specifications.
Remedy
Check the specifications.
125
IB-1501279-H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents