M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P32
Illegal address
Details
An address not listed in the specifications has been used.
Remedy
Correct the program address.
Correct the parameter settings.
Check the specifications.
P33
Format error
Details
The command format in the program is not correct.
Remedy
Correct the program.
P34
Illegal G code
Details
The commanded G code is not in the specifications.
An illegal G code was commanded during the coordinate rotation command.
G51.2 or G50.2 was commanded when the rotary tool axis No. (the parameter "#1501polyax") was set to
"0".
G51.2 or G50.2 was commanded when the tool axis was set to the linear axis (the parameter "#1017 rot"
= 0).
Remedy
Check and correct the G code address in the program.
Check the parameter setting values.
P35
Setting value range over
Details
The setting range for the addresses has been exceeded.
Remedy
Correct the program.
P36
Program end error
Details
"EOR" has been read during tape and memory mode.
Remedy
Enter the M02 and M30 command at the end of the program.
Enter the M99 command at the end of the subprogram.
P37
O, N number zero
Details
"0" has been specified for program or sequence No.
Remedy
Designate program Nos. within a range from 1 to 99999999.
Designate sequence Nos. within a range from 1 to 99999999.
P38
No spec: Add. Op block skip
Details
"/n" has been issued while the optional block skip addition is not in the specifications.
Remedy
Check the specifications.
125