M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1313
TapDw1
Set the hole bottom wait time for synchronous tapping.
When P address is specified, the greater value will be used as the hole bottom wait time. When an in-position
check is performed at the hole bottom, the wait time will be provided after the completion of the in-position
check.
(Note) This parameter is valid only when "1" is set in "#1223 aux07/bit3" (synchronous tap in-position check
improvement) and "#1223 aux07/bit4" (synchronous tap hole bottom in-position check).
---Setting range---
0 to 999 (ms)
#1314
TapInp
Set the hole bottom in-position check width for synchronous tapping.
(Note) This parameter is valid only when "1" is set in "#1223 aux07/bit3" (synchronous tap in-position check
improvement) and "#1223 aux07/bit4" (synchronous tap hole bottom in-position check).
---Setting range---
0.000 to 99.999
(PR)
#1316
CrossCom
Select whether to use the common variables from #100100 to #800199.
0: Not use
1: Use
This parameter is valid only when the number of variable sets is set to 600 or more.
When this parameter is set to "1", variables from #100100 to #100110 will not be available as the system
variables for PLC data read function, and the setting of "#1052 MemVal" will be invalid.
(PR)
#1318
MacVcom
In a multi-part system configuration, select whether to use the machine tool builder macro variables (#450 to
#499, #80000 to #80049 and #80500 to #80649) in common to all part systems or individually for each part
system.
0 : #450 to #499, #80000 to #80049 and #80500 to #80649 are used in common.
1 : #450 to #499 are used in common to part systems.
#80000 to #80049 and #80500 to #80649 are individual for each part system.
2 : #450 to #499 are individual for each part system.
#80000 to #80049 and #80500 to #80649 are common to part systems.
3 : #450 to #499, #80000 to #80049 and #80500 to #80649 are used individually for each part system.
#1319
Grp24_mdrst_off
[M8]
Select whether or not to retain the G group 24 modal state (G188/G189) after modal retention reset.
0: Not initialize the G group 24 modal state even when you turn OFF the program format change request
signal (PFCHR) and press Cycle Start.
1: Determine the G group 24 modal state according to the program format change request signal (PFCHR)
when Cycle Start is pressed.
[C80]
Not used.
(PR)
#1324
Chop_R
Set the head No. of the R register used as the compensation amount save area during fixed compensation
amount method.
When the first number is an odd number, the operation message "Setting error" appears.
When the value overlaps with the chopping control data area, the operation message "Setting error" appears.
---Setting range---
8300 to 9782
(Only the even number)
(Within backup area)
IB-1501279-H
Synchronous tap hole bottom wait time
Synchronous tap in-position check width (tap axis)
Reference of common variables common for part sys-
tems
Machine tool builder macro variables for each part sys-
tem
G group 24 modal retention reset OFF
Chopping compensation value fixing method
434