M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#8724
Sensor T L comp No
[M8]
Specify the tool length compensation No. of touch probe that is used for measurement of rotation center error
or workpiece installation error.
Set the touch probe offset in the said number before measurement.
If the specified offset is significantly different, the sensor may be damaged.
---Setting range---
0 to 999
#12066
Tolerance ctrl ON
Select whether to enable the tolerance control.
0: Disable
1: Enable
(Note) Tolerance control is available only under SSS control.
To enable SSS control, set #8090 to 1.
#12067
Smth Corn spd coef
Set the compensation coefficient to adjust a path error or clamp speed in the corner while tolerance control
is ON.
This parameter is enabled during tolerance control. Thus set this parameter if you wish to use different clamp
speed according to ON/OFF of tolerance control.
When "0" is set in this parameter, the standard value (100%) is applied.
---Setting range---
0 to 2000(%)
#12068
Smoothing range
Spline interpolation 2: Smoothing range
Normally set 0 in this parameter.
If you run a program with short line segments and its reciprocating paths are uneven, set the parameter to
about 3 to 5 times the length of the programmed line segments.
---Setting range---
0.000 to 10.000 (mm)
#12069
Corner angle
Tolerance control: Corner recognition angle
Specify the corner recognition angle. Normally set 0 in this parameter.
---Setting range---
0.000 to 180.000 (°)
#19001
Syn.tap(,S)cancel
0: Retain the spindle speed (,S) in synchronous tap return
1: Cancel the spindle speed (,S) in synchronous tap return with G80
The same value as "#1223 aux07/bit6" will be reflected. When either setting changes, the other will change
accordingly.
#19002
Zero-point mark
[M8]
Select the position for displaying the zero point mark in the graphic trace and 2D check.
0: Machine coordinates zero point (same as conventional method)
1: Workpiece coordinate zero point
The same value as "#1231 set03/bit4" will be reflected. When either setting changes, the other will change
accordingly.
[C80]
Not used.
IB-1501279-H
212