M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P604

TLM illegal axis

Details
No axis was specified in the automatic tool length measurement block. Otherwise, two or more axes were spec-
ified.
Remedy
Specify only one axis.
P605
T & TLM command in a block
Details
The T code is in the same block as the automatic tool length measurement block.
Remedy
Specify the T code before the automatic tool length measurement block.
P606

T cmnd not found before TLM

Details
The T code was not yet specified in automatic tool length measurement.
Remedy
Specify the T code before the automatic tool length measurement block.
P607

TLM illegal signal

Details
The measurement position arrival signal turned ON before the area specified by the D command or "#8006
ZONE d". Otherwise, the signal remained OFF to the end.
Remedy
Correct the program.
P608
Skip during radius compen
Details
A skip command was issued during radius compensation processing.
Remedy
Issue a radius compensation cancel (G40) command or remove the skip command.
P610
Illegal parameter
Details
The parameter setting is not correct.
- G114.1 was commanded while the spindle synchronization was selected with the PLC interface signal.
- G110 was commanded while the mixed control (cross axis control) was selected with the PLC interface
signal.
- G125 was commanded while the control axis synchronization across part systems was selected with the
PLC interface signal.
- G126 was commanded while the control axis superimposition was selected with the PLC interface signal.
Remedy
Correct the settings of "#1514 expLinax (Exponential function interpolation linear axis)" and "#1515 ex-
pRotax (Exponential function interpolation rotary axis)".
- Correct the program.
- Correct the parameter settings.
P611
No spec: Exponential function
Details
There is no specification for the exponential interpolation.
Remedy
Check the specifications.