Plc Constants - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters

16.15 PLC Constants

#18001-
R7500,7501 - R7798,7799
18150
Set the value to be set in the data type R register used in the PLC program (ladder).
Even if the data is set in the R register that corresponds to the PLC side when this parameter is displayed.
The screen will not change.Enter a different screen once, and then select this screen again.
---Setting range---
-2 to the power of 31 to 2 to the power of 31 -1
#18151-
R8300,8301 - R9798,9799
18900
Set the value to be set in the data type R register(R8300 to R9799) used in the PLC program (ladder).
Even if the data is set in the R register that corresponds to the PLC side when this parameter is displayed,
the screen will not change. Enter a different screen once, and then select this screen again.
#18151 to #18900 is used as the PLC constant extended area.
The area is valid for the number of PLC constant extension points ("#1326 PLC Const Ext. Num" setting val-
ue), starting with #18151.
---Setting range---
-2 to the power of 31 to 2 to the power of 31 -1
IB-1501279-H
PLC constant (Base area)
PLC constant (Extension area)
630