Pointer Setting Error; Interrupt Pointer Setting Error; Parameter - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
14 Multi CPU Errors (A) [C80]
A01
Boot function execution error
Details
When the boot function is executed, the security key registered in the CPU module (or extended SRAM
cassette) does not match the one that locks the boot source program.
When the boot function is executed, the security key is not registered in the CPU module (or extended
SRAM cassette) even though the boot source program is locked with the security key.
Remedy
Check and correct the security key setting.
Delete the boot setting.
A01

Pointer setting error

Details
The total number of points of local and global pointers used in the program exceeded the points set in the
CPU parameters (pointer device area).
Remedy
Check the detailed information (error location information) of the error by executing module diagnostics
using the engineering tool, display the error program (step) by clicking the [Error Jump] button, and correct
the program.
Check and correct the pointer device area point setting in the CPU parameters.
A01
Pointer setting error
Details
The total number of points of pointertype labels used in the program exceeded the points set in the CPU
parameters (label assignment area).
Remedy
Check the detailed information (error location information) of the error by executing module diagnostics
using the engineering tool, display the error program (step) by clicking the [Error Jump] button, and correct
the program.
Check and correct the pointer-type label assignment area point setting in the CPU parameters.
A01
Pointer setting error
Details
Multiple global pointers with the same number are used in the program. (The pointer numbers are over-
lapping.)
Remedy
Check the detailed information (error location information) of the error by executing module diagnostics
using the engineering tool, display the error program (step) by clicking the [Error Jump] button, and correct
the program.
A01
Pointer setting error
Details
Multiple local pointers with the same number are used in the program. (The pointer numbers are overlap-
ping.)
Remedy
Check the detailed information (error location information) of the error by executing module diagnostics
using the engineering tool, display the error program (step) by clicking the [Error Jump] button, and correct
the program.
A01

Interrupt pointer setting error

Details
The interrupt pointer numbers used in the files are overlapping.
Remedy
Check the detailed information (error location information) of the error by executing module diagnostics
using the engineering tool, display the error program (step) by clicking the [Error Jump] button, and correct
the program.
IB-1501279-H
194
3005
3300
3301
3302
3303
3320