M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#3145
S_SigInSP
[M8]
This parameter specifies which observation speed change signal is input in the drive unit. The observation
speed change signal corresponds to the following bits of the parameter.
bit0: Observation speed change signal 1 is connected.
bit1: Observation speed change signal 2 is connected.
bit2: Observation speed change signal 3 is connected.
If the axis receives no observation speed change signal, set to "0000".
(Note) When a same setting value is set to more than one axis, or when more than one BIT is set to turn ON
for one axis, the alarm (Y20 0027) will occur.
---Setting range---
0000 to 0004 (HEX)
[C80]
Not used.
#3146
RatedOutL(PwrCal)
Specify the short-time rated output of the spindle motor (for L-coil).
This value is used for calculating the power consumption of the spindle motor.
---Setting range---
0 to 99999999 (W)
#3147
RatedOutH(PwrCal)
Specify the short-time rated output of the spindle motor (for H-coil).
This value is used for calculating the power consumption of the spindle motor.
This parameter is used also when the coil switch function is OFF.
---Setting range---
0 to 99999999 (W)
(PR)
#3148
sycmpctm
Temporary error cancel calculation delay time
When a period of time set in this parameter has elapsed after turning-ON of the spindle chuck close (SPC-
MPC) signal, you can temporarily cancel spindle sync error by turning ON the spindle sync error temporary
cancel (SPDRPO) signal.
If the specified time has not elapsed when the spindle sync error temporary cancel (SPDRPO) signal is
turned ON, temporary cancel of spindle sync error is enabled first when the time of this parameter has
elapsed.
When 0 is set in this parameter, the delay time will be 284(ms).
---Setting range---
0 to 3000 (msec)
(PR)
#3149
spsscfeed5
[M8]
Set the observation speed, which is at the machine end, in the multi-step speed monitor.
(Note) When the setting value is larger than 18000, the last 2 digits will be ignored.
Ex. 1234567 -> 1234500(deg/min)
---Setting range---
0 to 6553500 (deg/min)
[C80]
Not used.
Safety observation signal input
Short-time rated output for power computation (L-coil)
Short-time rated output for power computation (H-coil)
Temporary error cancel calculation delay time
Observation speed 5
567
IB-1501279-H