16 Machine Parameters
bit 3-0 : esn Sensitivity of estimated resonance frequency
Set the sensitivity of the estimated resonance frequency. Smaller setting value enables to detect smaller vi-
bration component, however, adaptive movement will be repeated frequently. Normally set this parameter to
"0".
0 : Normal setting (same sensitivity as A) 1 : Sensitivity high to F : Sensitivity low
#2316
SV116 SSF11
Not used. Set to "0000".
(PR)
#2317
SV117 RNG1ex
For high-accuracy binary resolution encoder, set the number of pulses to four bite data of SV117 (high-order)
and SV019 (low-order) by pulse (p).
When SV117=0, the setting unit of SV019 is (kp).
Refer to SV019 for details.
Related parameters: SV019, SV020, SV118
---Setting range---
-1 to 32767
(PR)
#2318
SV118 RNG2ex
When using high-accuracy binary resolution encoder, set the number of pulses to four bite data of SV118
(high-order) and SV020 (low-order) by pulse (p).
When SV118=0, the setting unit of SV020 is (kp).
Refer to SV020 for details.
Related parameters: SV019, SV020, SV117
---Setting range---
-1 to 32767
#2319-2328
SV119 - SV128
Not used. Set to "0".
#2329
SV129 Kwf
Set the acceleration rate feed forward filter frequency in high-speed synchronous tapping control. The stan-
dard setting is "600".
Related parameters: SV244
---Setting range---
0 to 32767 (rad/s)
(PR)
#2330
SV130 RPITS
Set the base reference mark intervals of distance-coded reference scale. When the distance-coded refer-
ence scale is not used, set to "0".
The interval of basic reference mark (SV130) and auxiliary interval (SV131) must be in the specified relation-
ship. Other settings cause the initial parameter error (alarm 37).
Following is the specified relationship.
The quotient of (SV130×1000) / SV131 must be 4 or more and leaves no remainder.
Related parameters: SV081/bit7,3, SV131, SV134 to SV137
---Setting range---
0 to 32767 (mm)
Servo function 11
Expansion sub side encoder resolution
Expansion main side encoder resolution
Synchronous control feed forward filter frequency
Base reference mark interval