M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#2263
SV063 DA1MPY
Set output scale of the D/A output channel 1 in increment of 1/100.
When "0" is set, the magnification is the same as when "100" is set.
When the DC excitation is running (SV034/bit4=1):
Use this when the DC excitation is running (SV034/bit4=1) to adjust the initial magnetic pole position
(when measuring the magnetic pole shift amount) for linear motor and direct-drive motor.
Set the initial excitation time in DC excitation control.
Set 1000ms as standard.
When the magnetic pole shift amount measurement value is unsteady, adjust the value in increments of
500ms.
Related parameters: SV061, SV062
---Setting range---
-32768 to 32767 (1/100-fold)
When the DC excitation is running (SV034/bit4=1): 0 to 10000 (ms)
#2264
SV064 DA2MPY
Set output scale of the D/A output channel 2 in increment of 1/100.
When "0" is set, the magnification is the same as when "100" is set.
---Setting range---
-32768 to 32767 (1/100-fold)
#2265
SV065 TLC
The shape of the machine end is compensated by compensating the spring effect from the machine end to
the motor end.
Set the machine end compensation gain. Measure the error amount by roundness measurement and esti-
mate the setting value by the following formula.
Compensation amount (μm) = Command speed F(mm/min)2 * SV065 / (Radius R(mm) * SV003 *
16,200,000)
Set to "0" when not using.
---Setting range---
-30000 to 30000 (Acceleration ratio 0.1%)
#2266-2272
SV066 - SV072
This parameter is set automatically by the NC system.
(PR)
#2273
SV073 FEEDout
Set the specified speed.
Also set SV082/bit9,8 to output digital signal.
---Setting range---
0 to 32767 (r/min)
However, when SV033/bitD=1, the setting range is from 0 to 32767 (100mm/min).
(Only for MDS-E/EH and MDS-EM/EMH)
#2274-2280
SV074 - SV080
This parameter is set automatically by the NC system.
IB-1501279-H
D/A output ch1 output scale / Initial DC excitation time
D/A output ch2 output scale
Machine end compensation gain
Specified speed output speed