(PR)
#1213
proaxy
Set the length within the orthogonal coordinate of the inclined axis, a side of the triangle formed with the in-
clination angle.
---Setting range---
-9999.999 to 9999.999
(PR)
#1214
macaxy
Set the actual length of the base axis corresponding to the inclined axis, a side of the triangle formed with
the inclination angle.
---Setting range---
-9999.999 to 9999.999
(PR)
#1215
macaxx
Set the actual length of the inclined axis, a side of the triangle formed with the inclination angle.
---Setting range---
-9999.999 to 9999.999
#1216
extdcc
Set the upper limit value of the feedrate when the external deceleration signals are enabled.
---Setting range---
1 to 999999 (mm/min)
#1501
polyax
Specify the number of the rotational tool axis (servo axis) used for polygon machining (G51.2).
Set "0" when not using polygon machining (spindle-servo axis), or when using spindle-spindle polygon ma-
chining.
A value exceeding the base specification parameter "#1002 axisno" cannot be specified.
This parameter is valid when the G code system is 6 or 7 ("7" or "8" is set in base specification parameter
"#1037 cmdtyp").
---Setting range---
0 to controlled axis number
#1502
G0Ipfg
Select whether to perform a deceleration check when the travel direction is changed from G1 to G0.
0: Not perform
1: Perform
#1503
G1Ipfg
Select whether to perform a deceleration check when the travel direction is changed from G1 to G1.
0: Not perform
1: Perform
#1505
ckref2
Select whether the check is carried out at the specified position in manual second reference position return
mode upon completion of spindle orientation or at second reference position return interlock signal.
0: Upon completion of spindle orientation
1: At second reference position return interlock signal
#1506
F1_FM
Set the maximum value up to which the F 1-digit feedrate can be changed.
---Setting range---
0 to 1000000 (mm/min)
#1507
F1_K
Set the constant that determines the speed change rate per manual handle graduation in F 1-digit feedrate
change mode.
---Setting range---
0 to 32767
IB-1501279-H
Side 1 of inclination angle (for L system only)
Side 2 of inclination angle (for L system only)
Side 3 of inclination angle (for L system only)
External deceleration level
Rotational tool axis number (for L system only)
G1 -> G0 deceleration check
G1 -> G1 deceleration check
Second reference position return check
Upper limit of F1-digit feedrate
F 1-digit feedrate change constant
356

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents