Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 95

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E227 -0003
-04
Title
Power supply (24 V) error
Description
The 24 V port is turned off at the time of job completion.
of detection
Measures
Because the DC Controller turns OFF the 24 V Power
Supply when an error is detected, it is needed to restart
and check the power output before the machine detects
the error to determine whether the cause of the error is
power supply.
If there is no power output, power supply is the cause. If
there is power output, factor other than power supply can
be the cause of the error.
1. Turn OFF and then ON the power.
2. Check the connection between Reader and Printer,
and check that the Cable is not open-circuit.
3. Check the 24 V port of the Reader Controller PCB and
DADF Driver PCB.
4. Check the power supply and Relay PCB on the Printer
side.
5. Replace the Reader Controller PCB and DADF Driver
PCB.
E227 -0004
-04
Title
Power supply (24 V) error
Description
The 24 V port is turned off at the time of load drive.
of detection
Measures
Because the DC Controller turns OFF the 24 V Power
Supply when an error is detected, it is needed to restart
and check the power output before the machine detects
the error to determine whether the cause of the error is
power supply.
If there is no power output, power supply is the cause. If
there is power output, factor other than power supply can
be the cause of the error.
1. Turn OFF and then ON the power.
2. Check the connection between Reader and Printer,
and check that the Cable is not open-circuit.
3. Check the 24 V port of the Reader Controller PCB and
DADF Driver PCB.
4. Check the power supply and Relay PCB on the Printer
side.
5. Replace the Reader Controller PCB and DADF Driver
PCB.
Description
E
Detailed
Occurance
Items
code
code
area
E227 -0101
-04
Title
Power supply (24 V) error
Description
The 24 V port is turned off at the time of power-on at
of detection
DADF.
Measures
Because the DC Controller turns OFF the 24 V Power
Supply when an error is detected, it is needed to restart
and check the power output before the machine detects
the error to determine whether the cause of the error is
power supply.
If there is no power output, power supply is the cause. If
there is power output, factor other than power supply can
be the cause of the error.
1. Turn OFF and then ON the power.
2. Check the connection between Reader and Printer,
3. Check the 24 V port of the Reader Controller PCB and
4. Check the power supply and Relay PCB on the Printer
5. Replace the Reader Controller PCB and DADF Driver
E227 -0102
-04
Title
Power supply (24 V) error
Description
The 24 V port is turned off at the time of job start at
of detection
DADF.
Measures
Because the DC Controller turns OFF the 24 V Power
Supply when an error is detected, it is needed to restart
and check the power output before the machine detects
the error to determine whether the cause of the error is
power supply.
If there is no power output, power supply is the cause. If
there is power output, factor other than power supply can
be the cause of the error.
1. Turn OFF and then ON the power.
2. Check the connection between Reader and Printer,
3. Check the 24 V port of the Reader Controller PCB and
4. Check the power supply and Relay PCB on the Printer
5. Replace the Reader Controller PCB and DADF Driver
Description
and check that the Cable is not open-circuit.
DADF Driver PCB.
side.
PCB.
and check that the Cable is not open-circuit.
DADF Driver PCB.
side.
PCB.
3
3-69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents