COPIER> OPTION> FNC-SW
LOCLFIRM
Set to allow firmware update by file
Lv.1 Details
To set whether to permit the user (administrator) to update the
firmware from the remote UI using a local file.
This update is executed as a measure for vulnerability in emergency
situations.
Use case
When prohibiting the administrator to update the firmware using a file
Display/adj/set range
0 to 1
0: Disabled, 1: Enabled
Default value
1
RSHDW-SW
ON/OFF of remote shutdown
Lv.1 Details
A shared multi-function machine is not likely to be shut down at
power failure. Set ON/OFF of the remote shutdown function to
prevent accident.
When "1: ON" is set, the machine can be shut down from the remote
shutdown menu displayed in the remote UI.
Use case
When preventing an accident at specified power-off time.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
T1HP-POS
Set pry-trns diseng/eng pstn:initial VL
Lv.1 Details
To set the engagement or disengagement position as the home
position of the Primary Transfer Rollers (Y, M, C).
When "0: Engagement position" is set, the Primary Transfer Rollers
of 4 colors engage the ITB in the initial state.
When "1: Disengagement position" is set, the Primary Transfer Roller
of Bk only engages the ITB in the initial state.
Set "0: Engagement position" if you give priority to the first copy time
5
in the color mode.
Set "1: Disengagement position" if you give priority to the first copy
time in the B&W mode.
Use case
Upon user's request (Frequency to use color/B&W)
Display/adj/set range
0 to 1
0: Engagement position, 1: Disengagement position
MC-FANSW
Set of Controller Cooling Fan control
Lv.1 Details
To set full speed/half speed to fan control of the Controller Cooling
Fan 1 and 2.
When "1: Full speed" is set, the heat exhaust efficiency is enhanced.
Use case
• When HDD damage occurs multiple times
• When the machine is installed in high temperature environment in
which HDD damage is likely to occur
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Half speed, 1: Full speed
Default value
0
5-332
COPIER> OPTION> FNC-SW
OP-FAN
Setting of Anti-adhesion Fan airflow
Lv.2 Details
In the normal sequence, the Anti-adhesion Fan is set to OFF for the
reverse delivery, and 1/1 speed for the straight delivery or 2-sided
delivery.
Set the airflow of the Anti-adhesion Fan when the delivery adhesion
occurs or the delivery stackability decreases.
Set to 1 (1/2 speed) or 2 (1/1 speed) when the delivery adhesion
occurs at the time of the reverse delivery.
Set to 1 (1/2 speed) or 3 (OFF) when the delivery stackability
decreases at the time of the straight delivery or the 2-sided delivery.
Use case
• When the delivery adhesion occurs at the time of the reverse
delivery
• When the delivery stackability is low at the time of the straight
delivery or the 2-sided delivery
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
• When changing the value from 3 to 1 or 2, the delivery stackability
decreases.
• When changing the value from 2 to 1 or 3, the delivery adhesion
may deteriorate.
Display/adj/set range
0 to 3
0: Normal sequence, 1: 1/2 speed, 2: 1/1 speed, 3: OFF
Default value
0
BXNUPLOG
ON/OFF of Nup log at Inbox print
Lv.2 Details
To set whether to keep Nup log at Inbox print.
Use case
When keeping Nup log at Inbox print
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
At normal service: 0, At customization: 1
BUSI-SW
Setting of customized function
Lv.1 Details
To set the function in accordance with the customized specification.
Use case
When installing the customized machine
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Standard, 1: Customization
Default value
0
SDLMTWRN
Cpcty warn dis ON/OFF at E-mail/I-Fax TX
Lv.1 Details
To set whether to display the warning message when sending data
that exceeds the upper limit value for the transmission data size via
E-mail/I-Fax.
Use case
For customization
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Related user mode
Function Settings> Send> E-Mail/I-Fax Settings> Maximum Data
Size for Sending