COPIER> OPTION> IMG-DEV
2S-SS-3C
Adj YMC developer ejectn block: 1/2 SPD
Lv.2 Details
When processing many jobs at 1/2 speed (heavy paper), the
developer might increase or decrease too much.
To keep the proper developer amount, adjust the number of supply
blocks until transition to YMC-color developer forcible ejection.
Use case
When the developer increases or decreases too much due to
frequent use of 1/2 speed (heavy paper)
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 5
Default value
0
2S-SS-K
Adj Bk developer ejectn block: 1/2 SPD
Lv.2 Details
When processing many jobs at 1/2 speed (heavy paper), the
developer might increase or decrease too much.
To keep the proper developer amount, adjust the number of supply
blocks until transition to Bk-color developer forcible ejection.
Use case
When the developer increases or decreases too much due to
frequent use of 1/2 speed (heavy paper)
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 5
Default value
0
3S-SS-3C
Adj YMC developer ejectn block: 1/3 SPD
Lv.2 Details
When processing many jobs at 1/3 speed (heavy paper), the
developer might increase or decrease too much.
To keep the proper developer amount, adjust the number of supply
blocks until transition to YMC-color developer forcible ejection.
Use case
When the developer increases or decreases too much due to
frequent use of 1/3 speed (heavy paper)
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 5
Default value
0
3S-SS-K
Adj Bk developer ejectn block: 1/3 SPD
Lv.2 Details
When processing many jobs at 1/3 speed (heavy paper), the
developer might increase or decrease too much.
To keep the proper developer amount, adjust the number of supply
blocks until transition to Bk-color developer forcible ejection.
Use case
When the developer increases or decreases too much due to
frequent use of 1/3 speed (heavy paper)
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 5
Default value
0
■ IMG-LSR
PRI-FAN
Lv.2 Details
Use case
Display/adj/set range
Default value
T-5-63
COPIER> OPTION> IMG-LSR
Setting of Primary Charge Fan ON timing
To set the timing to forcibly turn ON the Primary Charging Suction
Fan, Primary Charging Exhaust Fan and Developing/Pre-transfer
Charging Fan.
When "1" is set, they are always turned ON by full speed and when "2"
is set, they are always turned ON by half speed during power-ON.
When image is smeared by the drum
0 to 2
0: Release forcible turn ON, 1: Always ON by full speed, 2: Always
ON by half speed
0