E
Detailed
Occurance
Items
code
code
area
E001 -0013
-05
Title
Fixing sub thermistor 2 (THM1-3) abnormal temperature
rise (circuit abnormality)
Description
Fixing sub thermistor 2 (THM1-3) detected abnormal
of detection
high temperature. (software detection)
Measures
Check the detection temperature of the fixing sub
thermistor 2 (THM1-3) in service mode (COPIER>
DISPLAY> ANALOG> FIX-UE2).
A. In case that the detection temperature is 250 degC
B. In case that the detection temperature is other than
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
E001 -0102
-05
Title
Abnormal temperature rise of pressure subthermistor 1
(THM3) (circuit failure)
Description
Pressure subthermistor 1 (THM3) sensed an abnormal
of detection
high temperature. (ASIC detection)
Measures
Check the detection temperature of the pressure
sub thermistor 1 (THM3) in service mode (COPIER>
DISPLAY> ANALOG> FIX-LE).
A. In case that the detection temperature is 250 degC
B. In case that the detection temperature is other than
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
Description
A-1. The cable of the fixing sub thermistor 2 is
caught -> replace the fixing belt unit
250 degC
B-1. Location of the fixing main thermistor is
inappropriate -> replace the fixing belt unit
B-2. Replace the DC controller PCB
A-1. The cable of the pressure sub thermistor 1 is
caught -> replace the pressure stay
250 degC
B-1. The pressure main thermistor is disconnected,
the harness is disconnected, foreign substance
is gotten in, or failure -> replace the main
thermistor or pressure stay
B-2. Replace the DC controller PCB
E
Detailed
Occurance
Items
code
code
area
E001 -0103
-05
Title
Abnormal temperature rise of pressure subthermistor 2
(THM4) (circuit failure)
Description
Pressure subthermistor 2 (THM4) sensed an abnormal
of detection
high temperature. (ASIC detection)
Measures
Check the detection temperature of the pressure
sub thermistor 2 (THM4) in service mode (COPIER>
DISPLAY> ANALOG> FIX-LE2).
A. In case that the detection temperature is 250 degC
B. In case that the detection temperature is other than
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
E001 -0111
-05
Title
Pressure main thermistor abnormal temperature rise
(circuit abnormality)
Description
Pressure main thermistor (THM2) detected abnormal
of detection
high temperature. (software detection)
Measures
Check the detection temperature of the pressure
main thermistor (THM2) in service mode (COPIER>
DISPLAY> ANALOG> FIX-LC).
A. In case that the detection temperature is 250 degC
B. In case that the detection temperature is other than
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
Description
A-1. The cable of the pressure sub thermistor 2 is
caught -> replace the pressure stay
250 degC
B-1. The pressure main thermistor is disconnected,
the harness is disconnected, foreign substance
is gotten in, or failure -> replace the main
thermistor or pressure stay
B-2. Replace the DC controller PCB
A-1. The cable of the pressure main thermistor is
caught -> replace the thermistor or the pressure
stay
250 degC
B-1. Replace the DC controller PCB
3