■ DPC
COPIER> FUNCTION> DPC
DPC
Execution of potential control
Lv.1 Details
To execute potential control for the Photosensitive Drum manually. (It
is usually executed automatically.)
When this item is executed, the same condition is set for
development of plain paper and coated paper.
Use case
When checking potential control operation
Adj/set/operate method Select the item, and then press OK key.
Caution
Since the same condition is set for development of plain paper and
coated paper groups, be sure to execute D-max control for both
groups after execution of this item.
Required time
Approx. 30 seconds
OFST
Potential adjustment of Potential Sensor
Lv.1 Details
To adjust the detection potential offset value of the Potential Sensor
automatically.
Use case
• When replacing the Photosensitive Sensor
• At diagnosis for a failure of the Photosensitive Sensor
Adj/set/operate method Select the item, and then press OK key.
Caution
An error is displayed when disconnection/connection failure/
installation failure occurs to the Potential Sensor at the time of
replacement. In this case, manually set the value to 0 by EPOTOFST
and then make an adjustment.
Required time
Approx. 4 seconds
Related service mode
COPIER> ADJUST> V-CONT> EPOTOFST
DRM-RSET
Exe of all color Drums replacement mode
Lv.1 Details
When replacement of Drum Unit is completed within 30 minutes,
warm-up rotation may not be executed at power-off/on because of
high fixing temperature. In such cases, drum potential becomes
unstable, causing an image failure to occur. To prevent this symptom,
this item forcibly executes the same operation as warm-up rotation.
At this time, laser power values, etc., that were corrected according
to drum counter for all colors, total charging time, target Vd values
for potential control and drum durability are reset.
Use case
When replacing the Drum Units for all colors
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
When the drum replacement mode is enabled, it becomes disabled
automatically after execution.
Caution
Be sure to execute this item after replacement of the Drum Units for
all colors.
Display/adj/set range
0 to 1
0: Disabled (Not executed), 1: Enabled (Executed)
Required time
Approx. 2 minutes
Related service mode
COPIER> FUNCTION> DPC> DRMRSETY, DRMRSETM,
DRMRSETC, DRMRSETK
COPIER> FUNCTION> DPC
DRMRSETY
Forcible exe of Y Drum replacement mode
Lv.1 Details
When replacement of Drum Unit is completed within 30 minutes,
warm-up rotation may not be executed at power-off/on because of
high fixing temperature. In such cases, drum potential becomes
unstable, causing an image failure to occur. To prevent this symptom,
this item forcibly executes the same operation as warm-up rotation.
At this time, laser power values, etc., that were corrected according
to Y drum counter, total charging time, target Vd values for potential
control and drum durability are reset.
Use case
• When detection of the Drum Unit replacement has failed
• When the Drum Unit used in other machine for a while is used as
a dummy unit
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
When the drum replacement mode is enabled, it becomes disabled
automatically after execution.
Caution
Use a Drum Unit that is not close to the end of life as a dummy unit.
When using a Drum Unit that is close to the end of life, it affects the
life of developer, etc.
Display/adj/set range
0 to 1
0: Disabled (Not executed), 1: Enabled (Executed)
Required time
Approx. 2 minutes
Related service mode
COPIER> FUNCTION> DPC> DRM-RSET, DRMRSETM,
DRMRSETC, DRMRSETK
5