E
Detailed
Occurance
Items
code
code
area
E905 0012
-05
Title
Failure of the air assist for Cassette 3 of the multi-
cassette deck
Description
Even when the maximum LOW interval was passed,
of detection
there was no change in the signal.
Measures
1. Displacement of the connector of the swing HP sensor
(S316).
2. Failure of the swing sensor (S316).
3. Failure of the swing motor (M302).
4. Failure of the deck driver PCB.
5. Failure of the DC controller PCB in the host machine.
0020
-05
Title
Failure of the multi-cassette deck power supply cooling
fan
Description
A failure was detected at the power supply cooling fan
of detection
(FM001).
Measures
1. Check the connection of the connector.
2. Replace the power supply cooling fan (FM001).
E906 0001
-05
Title
POD deck light air heater high temperature error
Description
A temperature over 120 degreeC was detected for 1
of detection
second consecutively.
Measures
1. Failure of the environment sensor (SR1)
2. Failure of the warm air fan (FAN1)
3. Failure of the cool air fan (FAN2)
4. Failure of the additional fan (FAN3)
5. Failure of the air heater (H1)
6. Failure of the deck controller PCB (UN1)
0002
-05
Title
POD deck light air heater low temperature error
Description
The heater is not placed in the Ready status even when
of detection
a specified period of time has elapsed.
Measures
1. Failure of the environment sensor (SR1)
2. Failure of the warm air fan (FAN1)
3. Failure of the cool air fan (FAN2)
4. Failure of the additional fan (FAN3)
5. Failure of the air heater (H1)
6. Failure of the deck controller PCB (UN1)
0010
-05
Title
High temperature error at the air heater for the upper
multi-cassette deck
Description
A high-temperature error was detected at the upper multi-
of detection
cassette deck.
Measures
1. Failure of the air heater unit (HT101).
2. Failure of the air heater PCB harness.
3. Failure of the upper deck air heater PCB.
4. Failure of the deck driver PCB.
5. Failure of the DC controller PCB in the host machine.
Description
E
Detailed
Occurance
Items
code
code
area
E906 0011
-05
Title
High temperature error at the air heater for the middle
multi-cassette deck
Description
A high-temperature error was detected at the middle
of detection
multi-cassette deck.
Measures
1. Failure of the air heater unit (HT201).
2. Failure of the air heater PCB harness.
3. Failure of the middle deck air heater PCB.
4. Failure of the deck driver PCB.
5. Failure of the DC controller PCB in the host machine.
0012
-05
Title
High temperature error at the air heater for the lower
multi-cassette deck
Description
A high-temperature error was detected at the lower multi-
of detection
cassette deck.
Measures
1. Failure of the air heater unit (HT301).
2. Failure of the air heater PCB harness.
3. Failure of the lower deck air heater PCB.
4. Failure of the deck driver PCB.
5. Failure of the DC controller PCB in the host machine.
0020
-05
Title
Low temperature error at the air heater for the upper
multi-cassette deck
Description
A low-temperature error was detected at the upper multi-
of detection
cassette deck.
Measures
1. Failure of the air heater unit (HT101).
2. Failure of the air heater PCB harness.
3. Failure of the upper deck air heater PCB.
4. Failure of the AC distribution PCB (F6).
5. Failure of the deck driver PCB.
6. Failure of the DC controller PCB in the host machine.
0021
-05
Title
Low temperature error at the air heater for the middle
multi-cassette deck
Description
A low-temperature error was detected at the middle multi-
of detection
cassette deck.
Measures
1. Failure of the air heater unit (HT201).
2. Failure of the air heater PCB harness.
3. Failure of the middle deck air heater PCB.
4. Failure of the AC distribution PCB (F6).
5. Failure of the deck driver PCB.
6. Failure of the DC controller PCB in the host machine.