E002 -0005
-05
Title
Description
of detection
Measures
3
3-8
Description
Insufficient fixing belt temperature rise 4
In a warm-up, the temperature of fixing main thermistor
(THM1-1) does not reach to 150 degrees Celsius within
120 seconds after reaching to 130 degrees Celsius.
Check the detection temperature of the thermistor in
service mode (COPIER> DISPLAY> ANALOG> FIX-xx).
A. In case that either one of the thermistor detection
temperature is risen
A-1. Check the fixing belt unit (to see if the
location of the thermistor is inappropriate or the
thermistor failure) -> replace the fixing belt unit
A-2. Faulty drawer connector -> clean the drawer
connector or replace the fixing drawer cable
B. In case that neither of them are not risen
B-1. Check the connection of the fixing thermistor
(to see if the connection of the drawer is
faulty, the connector is physically removed or
disconnected) -> replace the fixing belt unit
B-2. Check the connection of the IH power
connector (to see if the connector is physically
removed or disconnected, or the cable is caught)
B-3. Replace the IH power unit
B-4. Replace the DC controller PCB
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
E
Detailed
Occurance
Items
code
code
area
E002 -0006
-05
Title
Insufficient fixing belt temperature rise 5
Description
In a warm-up, the temperature of fixing main thermistor
of detection
(THM1-1) does not reach to the specified temerature
for temperature control after reaching to 150 degrees
Celsius.
Measures
Check the detection temperature of the thermistor in
service mode (COPIER> DISPLAY> ANALOG> FIX-xx).
A. In case that either one of the thermistor detection
B. In case that neither of them are not risen
NOTE: After performing the above remedy work, go
through the following to clear the error: COPIER>
FUNCTION> CLEAR> ERR
Description
temperature is risen
A-1. Check the fixing belt unit (to see if the
location of the thermistor is inappropriate or the
thermistor failure) -> replace the fixing belt unit
A-2. Faulty drawer connector -> clean the drawer
connector or replace the fixing drawer cable
B-1. Check the connection of the fixing thermistor
(to see if the connection of the drawer is
faulty, the connector is physically removed or
disconnected) -> replace the fixing belt unit
B-2. Check the connection of the IH power
connector (to see if the connector is physically
removed or disconnected, or the cable is caught)
B-3. Replace the IH power unit
B-4. Replace the DC controller PCB