COPIER> DISPLAY> DPOT
LS-PWM-Y
Display of Y-color PWM setting value
Lv.2 Details
To display the PWM value set for Y.
Use case
When checking the current PWM setting
Display/adj/set range
0 to 100
Unit
1%
Appropriate target value 50 to 100
Related service mode
COPIER> DISPLAY> DPOT> LS-PWM-M, LS-PWM-C, LS-PWM-K
LS-PWM-M
Display of M-color PWM setting value
Lv.2 Details
To display the PWM value set for M.
Use case
When checking the current PWM setting
Display/adj/set range
0 to 100
Unit
1%
Appropriate target value 50 to 100
Related service mode
COPIER> DISPLAY> DPOT> LS-PWM-Y, LS-PWM-C, LS-PWM-K
LS-PWM-C
Display of C-color PWM setting value
Lv.2 Details
To display the PWM value set for C.
Use case
When checking the current PWM setting
Display/adj/set range
0 to 100
Unit
1%
Appropriate target value 50 to 100
Related service mode
COPIER> DISPLAY> DPOT> LS-PWM-Y, LS-PWM-M, LS-PWM-K
LS-PWM-K
Display of Bk-color PWM setting value
Lv.2 Details
To display the PWM value set for Bk.
Use case
When checking the current PWM setting
Display/adj/set range
0 to 100
Unit
1%
Appropriate target value 50 to 100
Related service mode
COPIER> DISPLAY> DPOT> LS-PWM-Y, LS-PWM-M, LS-PWM-C
CHG-DCY2
Dis of pry chg DC voltg (Y):1/2, 1/3 SPD
Lv.1 Details
To display the primary charging DC voltage lastly applied to the
Charging Roller (Y) at 1/2 and 1/3 speed.
Use case
When checking
Display/adj/set range
0 to 1000
Unit
V
Appropriate target value 400 to 900
CHG-DCM2
Dis of pry chg DC voltg (M):1/2, 1/3 SPD
Lv.1 Details
To display the primary charging DC voltage lastly applied to the
Charging Roller (M) at 1/2 and 1/3 speed.
Use case
When checking
Display/adj/set range
0 to 1000
Unit
V
Appropriate target value 400 to 900
COPIER> DISPLAY> DPOT
CHG-DCC2
Dis of pry chg DC voltg (C):1/2, 1/3 SPD
Lv.1 Details
To display the primary charging DC voltage lastly applied to the
Charging Roller (C) at 1/2 and 1/3 speed.
Use case
When checking
Display/adj/set range
0 to 1000
Unit
V
Appropriate target value 400 to 900
LPGAIN-Y
Dis of Y-color laser power gain value
Lv.2 Details
To display the gain value of Y laser power by D-max control.
Use case
When checking D-max control results
Display/adj/set range
-100 to 100
Unit
%
Appropriate target value 0
Related service mode
COPIER> DISPLAY> DPOT> LPGAIN-M, LPGAIN-C
LPGAIN-M
Dis of M-color laser power gain value
Lv.2 Details
To display gain value of M laser power by D-max control.
Use case
When checking D-max control results
Display/adj/set range
-100 to 100
Unit
%
Appropriate target value 0
Related service mode
COPIER> DISPLAY> DPOT> LPGAIN-Y, LPGAIN-C
LPGAIN-C
Dis of C-color laser power gain value
Lv.2 Details
To display gain value of C laser power by D-max control.
Use case
When checking D-max control results
Display/adj/set range
-100 to 100
Unit
%
Appropriate target value 0
Related service mode
COPIER> DISPLAY> DPOT> LPGAIN-Y, LPGAIN-M