COPIER> COUNTER> DRBL-1
FX-BLT-U
Fixing Belt Unit parts counter
Lv.1 Details
To display the accumulated number of paper transported through
Fixing Belt Unit on a small size conversion basis.
1st line: Total counter value from the previous replacement
2nd line: Estimated life
By pressing Clear key, the accumulated number of paper transported
through Fixing Belt Unit, the running time of the Fixing Belt Unit (FX-
U-TM1 to 8), and displacement control steering setting value (FX-U-
STR) are reset.
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
Related service mode
COPIER> DISPLAY> FIXING> FX-U-TM1 to 8, FX-U-STR
FX-BLT-L
Pressure Belt Unit parts counter
Lv.1 Details
To display the accumulated number of paper transported through
Pressure Belt Unit on a small size conversion basis.
1st line: Total counter value from the previous replacement
2nd line: Estimated life
By pressing Clear key, the accumulated number of paper transported
through Pressure Belt Unit, the running time of the Fixing Belt Unit
(FX-U-TM1 to 8), and displacement control steering setting value
(FX-U-STR) are reset.
Use case
When checking the consumption level of parts/replacing the parts
5
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
Related service mode
COPIER> DISPLAY> FIXING> FX-L-TM1 to 8, FX-MTR2 to 8
PT-DR-Y
Y Photosensitive Drum parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
5-464
COPIER> COUNTER> DRBL-1
PT-DR-M
M Photosensitive Drum parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PT-DR-C
C Photosensitive Drum parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
1TR-RL-Y
Primary Transfer Roller(Y) parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
1TR-RL-M
Primary Transfer Roller(M) parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0