Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 378

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

Address
bit
Name
P027
15
Drum ITB Driver PCB_RESET UN6
14
Fixing Feed Driver PCB_
RESET
13
Pickup Feed Driver PCB_
RESET
12
Hopper Driver PCB_RESET
11
Buffer Driver PCB_RESET
10
Fixing Feed Drawer Connect A
9
Fixing Feed Drawer Connect B
5
8
Buffer Unit Decurler Unit
Connect
7
Multi Deck Connect
6
Fixing Thermistor Connect
5
Pressure Thermistor Connect
4
DCON_LIVE Signal
3
Reserve
2
For R&D use
1
Transparency Sensor
0
Laser Interface PCB Ready
Signal
5-150
Symbol
Remarks
0: Drum ITB Driver PCB RESET
1: Clear Drum ITB Driver PCB
RESET
* Cable disconnection or trapped
cable is 0
UN5
0: Fixing Feed Driver PCB RESET
1: Clear Fixing Feed Driver PCB
RESET
* Cable disconnection or trapped
cable is 0
UN4
0: Pickup Feed Driver PCB RESET
1: Clear Pickup Feed Driver PCB
RESET
* Cable disconnection or trapped
cable is 0
UN3
0: Hopper Driver PCB RESET
1: Clear Hopper Driver PCB RESET
* Cable disconnection or trapped
cable is 0
UN150
0: Buffer Driver PCB RESET
1: Clear Buffer Driver PCB RESET
* Cable disconnection or trapped
cable is 0
0: Open
1: Connect
* Cable disconnection or trapped
cable is 0
0: Open
1: Connect
* Cable disconnection or trapped
cable is 0
0: Open
1: Connect
0: Open
1: Connect
THM1-1/
0: Open
-2/-3
1: Connect
THM2/3/4 L: OPEN
H: Connect
DCON_LIVE signal of Controller PCB
DDIP
PS29
1: Paper
0: Transparency
UN100
1: Detect
After 1 is detected, Clear reset
Address
bit
Name
P028
15
Multi-purpose Tray Cover
Sensor
14
Pressure Belt Position Sensor
1
13
Pressure Belt Position Sensor
2
12
Primary Transfer Roller
Disengagement HP Sensor
11
Reserve
10
Reserve
9
Power Supply Cooling Fan
(38V) Lock Detection
8
IH Power Supply Fan Lock
Detection
7
Fixing Feed Unit Switch
6
Interlock Error Detection
5
Fixing Thermistor Excessive
Temperature Rise Detection
Error
4
Fixing Thermistor Open Circuit
Detection
3
IH Power Supply RMT
Detection
2
Primary Charging Suction Fan
Lock Detection
1
For R&D use
0
Fixing Belt Displacement
Hardware Error Detection
Symbol
Remarks
PS79
0: Open
PS76
PS76/PS77
1/1: Error
0/1: Belt position +1.0 (1 step
backward)
0/0: Center
1/0: Belt position -1.0 (1 step forward)
PS77
PS76/PS77
1/1: Error
0/1: Belt position +1.0 (1 step
backward)
0/0: Center
1/0: Belt position -1.0 (1 step forward)
PS4
0: HP (engage)
FM14
1: Error (while the Fan is driven)
FM7
1: Error (while the Fan is driven)
SW7
0: Close
SW1/
Regarding SW1, SW2, SW3, and
SW2/
SW5
SW3/SW5
1: Relay is ON with all above
switches
0: Relay is OFF with at least one of
the above switches
THM1-1
0: Normal
1: Excessive temperature rise ERR
THM1-1
0: Normal
1: Fixing Thermistor open circuit ERR
0: OFF
1: Enable
FM2
1: Error (while the Fan is driven)
1: Error

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents