COPIER> DISPLAY> HV-STS
PRIACV-Y
Discharge current ctrl setting voltg (Y)
Lv.2 Details
To display the AC voltage setting value to be Applied to the Y
Charging Roller At 1/1 speed derived from the latest discharge
current control.
Use case
When checking the voltage value (Y) for discharge current control
Display/adj/set range
0 to 3000
Unit
V
Appropriate target value 1250 to 2500
Related service mode
COPIER> DISPLAY> HV-STS> PRIACV-M, PRIACV-C, PRIACI-Y,
PRIACI-M, PRIACI-C, PRISMP-Y, PRISMP-M, PRISMP-C
COPIER> FUNCTION> MISC-P> DISCHG
PRIACV-M
Discharge current ctrl setting voltg (M)
Lv.2 Details
To display the AC voltage setting value to be Applied to the M
Charging Roller At 1/1 speed derived from the latest discharge
current control.
Use case
When checking the voltage value (M) for discharge current control
Display/adj/set range
0 to 3000
Unit
V
Appropriate target value 1250 to 2500
Related service mode
COPIER> DISPLAY> HV-STS> PRIACV-Y, PRIACV-C, PRIACI-Y,
PRIACI-M, PRIACI-C, PRISMP-Y, PRISMP-M, PRISMP-C
COPIER> FUNCTION> MISC-P> DISCHG
PRIACV-C
Discharge current ctrl setting voltg (C)
Lv.2 Details
To display the AC voltage setting value to be Applied to the C
Charging Roller At 1/1 speed derived from the latest discharge
current control.
Use case
When checking the voltage value (C) for discharge current control
Display/adj/set range
0 to 3000
Unit
V
Appropriate target value 1250 to 2500
Related service mode
COPIER> DISPLAY> HV-STS> PRIACV-Y, PRIACV-M, PRIACI-Y,
PRIACI-M, PRIACI-C, PRISMP-Y, PRISMP-M, PRISMP-C
COPIER> FUNCTION> MISC-P> DISCHG
2ATVC-M1
Sec Trns ATVC target current:B&W,1/1 SPD
Lv.2 Details
To display the decuple value of the target current At B&W 1/1 speed
derived from the latest secondary transfer Full ATVC control.
Use case
When judging whether the secondary transfer is appropriately set At
image failure
Caution
The correct value is not shown unless paper feed has triggered the
secondary transfer ATVC control After power-off/on.
Unit
uA
Appropriate target value 60 to 90
Related service mode
COPIER> ADJUST> HV-TR> 2TR-TGT1 to 8, TR-PPR1 to 8
COPIER> DISPLAY> HV-STS
2ATVC-F2
Sec Trns ATVC target current:clr,1/2 SPD
Lv.2 Details
To display the decuple value of the target current At full-color 1/2
speed derived from the latest secondary transfer Full ATVC control.
Use case
When judging whether the secondary transfer is appropriately set At
image failure
Caution
The correct value is not shown unless paper feed has triggered the
secondary transfer ATVC control After power-off/on.
Unit
uA
Appropriate target value 30 to 60
Related service mode
COPIER> ADJUST> HV-TR> 2TR-TGT1 to 8, TR-PPR1 to 8
2ATVC-M2
Sec Trns ATVC target current:B&W,1/2 SPD
Lv.2 Details
To display the decuple value of the target current At B&W 1/2 speed
derived from the latest secondary transfer Full ATVC control.
Use case
When judging whether the secondary transfer is appropriately set At
image failure
Caution
The correct value is not shown unless paper feed has triggered the
secondary transfer ATVC control After power-off/on.
Unit
uA
Appropriate target value 30 to 60
Related service mode
COPIER> ADJUST> HV-TR> 2TR-TGT1 to 8, TR-PPR1 to 8
2ATVC-F3
Sec Trns ATVC target current:clr,1/3 SPD
Lv.2 Details
To display the decuple value of the target current At full-color 1/3
speed derived from the latest secondary transfer Full ATVC control.
Use case
When judging whether the secondary transfer is appropriately set At
image failure
Caution
The correct value is not shown unless paper feed has triggered the
secondary transfer ATVC control After power-off/on.
Unit
uA
Appropriate target value 20 to 40
Related service mode
COPIER> ADJUST> HV-TR> 2TR-TGT1 to 8, TR-PPR1 to 8
2ATVC-M3
Sec Trns ATVC target current:B&W,1/3 SPD
Lv.2 Details
To display the decuple value of the target current At B&W 1/3 speed
derived from the latest secondary transfer Full ATVC control.
Use case
When judging whether the secondary transfer is appropriately set At
image failure
Caution
The correct value is not shown unless paper feed has triggered the
secondary transfer ATVC control After power-off/on.
Unit
uA
Appropriate target value 20 to 40
Related service mode
COPIER> ADJUST> HV-TR> 2TR-TGT1 to 8, TR-PPR1 to 8