Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 322

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

COPIER> DISPLAY> HT-C
DLT-A-Y2
ARCDAT scrn A Y-density differ (1/2 SPD)
Lv.2 Details
To display the difference between Y-patch target value and the
current value of screen A in ARCDAT control at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen A: High screen ruling screen
DLT-A-M2
ARCDAT scrn A M-density differ (1/2 SPD)
Lv.2 Details
To display the difference between M-patch target value and the
current value of screen A in ARCDAT control at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen A: High screen ruling screen
DLT-A-C2
ARCDAT scrn A C-density differ (1/2 SPD)
5
Lv.2 Details
To display the difference between C-patch target value and the
current value of screen A in ARCDAT control at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen A: High screen ruling screen
5-94
COPIER> DISPLAY> HT-C
DLT-A-K2
ARCDAT scrn A Bk-density differ(1/2 SPD)
Lv.2 Details
To display the difference between Bk-patch target value and the
current value of screen A in ARCDAT control at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen A: High screen ruling screen
DLT-B-Y2
ARCDAT scrn B Y-density differ (1/2 SPD)
Lv.2 Details
To display the difference between Y-patch target value and the
current value of screen B in ARCDAT control at 1/2 speed
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen B: Low screen ruling screen
DLT-B-M2
ARCDAT scrn B M-density differ (1/2 SPD)
Lv.2 Details
To display the difference between M-patch target value and the
current value of screen B in ARCDAT control at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen B: Low screen ruling screen