Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 289

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

COPIER> DISPLAY> ANALOG
DEVHUM2
Dis of C color Developing Ass'y humidity
Lv.2 Details
To display the humidity of the C Developing Assembly detected by
the Developing Assembly Inner Temperature Detection PCB (C/Bk).
Use case
When a failure occurs on the developing contrast
Display/adj/set range
0 to 100
Unit
%
Appropriate target value 5 to 80
Related service mode
COPIER> DISPLAY> ANALOG> DEVHUM1, DEVTEMP1,
DEVTEMP2
DEVTEMP2
Dis of C color Developing Ass'y temp
Lv.2 Details
To display the temperature of the C Developing Assembly detected
by the Developing Assembly Inner Temperature Detection PCB (C/
Bk).
Use case
When a failure occurs on the developing contrast
Display/adj/set range
0 to 100
Unit
Deg C
Appropriate target value 10 to 45
Related service mode
COPIER> DISPLAY> ANALOG> DEVHUM1, DEVHUM2,
DEVTEMP1
PDK-TEMP
Dis of POD Deck compartment temp
Lv.1 Details
To display the compartment temperature of POD Deck Lite.
It may be out of order if the indicated temperature is greatly different
from the machine right after power-on.
Display/adj/set range
0 to 60
Unit
Deg C
Related service mode
COPIER> DISPLAY> ANALOG> TEMP, PDK-HUM
PDK-HUM
Dis of POD Deck compartment humidity
Lv.1 Details
To display the compartment humidity of POD Deck Lite.
It may be out of order if the indicated humidity is greatly different
from the machine right after power-on.
Display/adj/set range
0 to 100
Unit
%
Related service mode
COPIER> DISPLAY> ANALOG> HUM, PDK-TEMP
MDK-TEMP
Dis of Multi Deck compartment temp
Lv.1 Details
To display the compartment temperature of the Multi Deck.
It may be out of order if the indicated temperature is greatly different
from the machine right after power-on.
Display/adj/set range
0 to 60
Unit
Deg C
Related service mode
COPIER> DISPLAY> ANALOG> TEMP, MDK-HUM
COPIER> DISPLAY> ANALOG
MDK-HUM
Dis of POD Deck compartment humidity
Lv.1 Details
To display the compartment humidity of the Multi Deck.
It may be out of order if the indicated humidity is greatly different
from the machine right after power-on.
Display/adj/set range
0 to 100
Unit
%
Related service mode
COPIER> DISPLAY> ANALOG> HUM, MDK-TEMP
DEVTEMP1
Dis of Y/M Developing Ass'y temperature
Lv.2 Details
To display the temperature of the Y and M Developing Assembly
detected by the Developing Assembly Inner Temperature Detection
PCB (Y/M).
Use case
When a failure occurs on the developing contrast
Display/adj/set range
0 to 100
Unit
Deg C
Appropriate target value 10 to 45
Related service mode
COPIER> DISPLAY> ANALOG> DEVHUM1, DEVHUM2,
DEVTEMP2
FX-MTR
Display of Fixing Motor current value
Lv.1 Details
To display the real-time current value of the Fixing Motor.
Use case
When checking the life of the Pressure Belt Unit
Unit
10 mA
FX-U-POS
Dis of Fixing Belt displacement state
Lv.1 Details
To display the Fixing Belt displacement state in real-time.
This shows the ON/OFF status of the Fixing Belt Position Sensor 1,
2 and the Fixing Belt HP Sensor.
Use case
When checking the Fixing Belt displacement control
Display/adj/set range
0 to 1
0: ON (Transmit light), 1: OFF (Block light)
Related service mode
COPIER> FUNCTION> FIXING> FX-UHP
FX-L-POS
Dis of Pressure Belt displacement state
Lv.1 Details
To display the Pressure Belt displacement state in real-time.
This shows the ON/OFF status of the Pressure Belt Position Sensor 1,
2 and the Pressure Belt HP Sensor.
Use case
When checking the Pressure Belt displacement control
Display/adj/set range
0 to 1
0: ON (Transmit light), 1: OFF (Block light)
Related service mode
COPIER> FUNCTION> FIXING> FX-LHP
■ CST-STS
COPIER> DISPLAY> CST-STS
WIDTH-MF
Dis of Multi-purpose Tray ppr width size
Lv.2 Details
To display the paper width size set on the Multi-purpose Tray.
Use case
When checking the paper width side set on the Multi-purpose Tray
Unit
mm
5
T-5-4
T-5-5
5-61

Hide quick links: