Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 433

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

COPIER> ADJUST> DENS
DMLMT-HM
M toner charging DC voltage upper limit
Lv.2 Details
To adjust the offset of the charging DC voltage upper limit for M in
D-max control.
Use case
When a failure occurs due to limiter of D-max control
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Execute Auto Adjust Gradation > Quick Adjust.
Caution
Do not use this at the normal service.
Display/adj/set range
-1500 to 1500
Unit
1 V
Appropriate target value 500 to 1000
Related user mode
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust
Gradation > Quick Adjust
DMLMT-HC
C toner charging DC voltage upper limit
Lv.2 Details
To adjust the offset of the charging DC voltage upper limit for C in
D-max control.
Use case
When a failure occurs due to limiter of D-max control
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Execute Auto Adjust Gradation > Quick Adjust.
Caution
Do not use this at the normal service.
Display/adj/set range
-1500 to 1500
Unit
1 V
Appropriate target value 500 to 1000
Related user mode
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust
Gradation > Quick Adjust
DMLMT-LY
Y toner charging DC voltage lower limit
Lv.2 Details
To adjust the offset of the charging DC voltage lower limit for Y in
D-max control.
Use case
When a failure occurs due to limiter of D-max control
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Execute Auto Adjust Gradation > Quick Adjust.
Caution
Do not use this at the normal service.
Display/adj/set range
-300 to 300
Unit
1 V
Related user mode
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust
Gradation > Quick Adjust
DMLMT-LM
M toner charging DC voltage lower limit
Lv.2 Details
To adjust the offset of the charging DC voltage lower limit for M in
D-max control.
Use case
When a failure occurs due to limiter of D-max control
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Execute Auto Adjust Gradation > Quick Adjust.
Caution
Do not use this at the normal service.
Display/adj/set range
-300 to 300
Unit
1 V
Related user mode
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust
Gradation > Quick Adjust
COPIER> ADJUST> DENS
DMLMT-LC
C toner charging DC voltage lower limit
Lv.2 Details
To adjust the offset of the charging DC voltage lower limit for C in
D-max control.
Use case
When a failure occurs due to limiter of D-max control
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Execute Auto Adjust Gradation > Quick Adjust.
Caution
Do not use this at the normal service.
Display/adj/set range
-300 to 300
Unit
1 V
Related user mode
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust
Gradation > Quick Adjust
CONT-Y
Toner Density Sensor (Y) control voltage
Lv.1 Details
To enter the density detection control voltage of the Toner Density
Sensor (Y).
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When the backup data is cleared by RAM clear, etc.
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
0 to 255
Appropriate target value 140 to 240
Related service mode
COPIER> DISPLAY> DENS> CONT-Y
CONT-M
Toner Density Sensor (M) control voltage
Lv.1 Details
To enter the density detection control voltage of the Toner Density
Sensor (M).
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When the backup data is cleared by RAM clear, etc.
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
After the setting value is changed, write the changed value in the
service label.
Display/adj/set range
0 to 255
Appropriate target value 140 to 240
Related service mode
COPIER> DISPLAY> DENS> CONT-M
5
5-205

Hide quick links:

Advertisement

Table of Contents
loading