COPIER> OPTION> FNC-SW
MIBCOUNT
Scope range set of Charge Counter MIB
Lv.2 Details
To set the range of counter information that can be obtained as MIB
(Management Information Base).
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2
0: All charge counters are obtained, 1: Only displayed counter* is
obtained, 2: All charge counters are not obtained
* : Counter specified by the following: COPIER > OPTION > USER >
COUNTER 1 to 6
Default value
0
Related service mode
COPIER> OPTION> USER> COUNTER1 to 6
MEAP-PRI
Setting of MEAP task priority
Lv.2 Details
Selecting ON increases MEAP task priority.
Use case
When improving processing performance of MEAP
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
CNTR-SW
Init of parts counter replacement timing
Lv.1 Details
To return the estimated life of parts counter to the initial value.
Use case
Upon user's request
Adj/set/operate method 1) Enter 0, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0: Returned to the initial value
Default value
0
5
W/RAID
Setting of RAID Board installation
Lv.1 Details
To set installation condition of RAID Board (HDD Mirroring Kit).
Select "1: Installed" when installing the RAID Board. Select "0: Not
installed" when removing the RAID Board.
Use case
When installing/removing RAID Board
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Not installed, 1: Installed
Default value
0
5-330
COPIER> OPTION> FNC-SW
PSWD-SW
Password type set to enter service mode
Lv.1 Details
To set the type of password that is required to enter when getting into
service mode.
2 types are available: one for "service technician" and the other for
"system administrator + service technician".
When selecting the type for "system administrator + service
technician", enter the password for service technician after the
password entry by the user's system administrator.
Use case
Upon request from the user who concerns security
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2
0: No password, 1: Service technician, 2: System administrator +
service technician
Default value
0
SM-PSWD
Password setting for service technician
Lv.2 Details
To set password for service technician that is used when getting into
service mode.
Use case
When password is required to get into service mode
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to select 1 or 2 with PSWD-SW in advance.
Display/adj/set range
1 to 99999999
Default value
11111111
Related service mode
COPIER> OPTION> FNC-SW> PSWD-SW
RPT2SIDE
Set of report 1sided/2-sided output
Lv.1 Details
To set whether to use 1-sided or 2-sided for report output of service
mode.
Use case
When making 2-sided report output to reduce the number of output
pages
Display/adj/set range
0 to 1
0: 1-sided, 1: 2-sided
Default value
1
Related service mode
COPIER> FUNCTION> MISC-P> P-PRINT
BRWS-FAV
Set of service browser favorite register
Lv.2 Details
To set whether to allow registration of favorites in the browser for
service.
When 1 is set, favorites in the browser for service can be edited, and
any URLs can be accessed.
Use case
When service engineers edit favorites in the browser for service
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Disabled, 1: Enabled
Default value
0