Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 153

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E602 -1123
-00
Title
Hard disk failure
Description
/APL_MEAP is abnormal
of detection
Measures
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
2. If not recovery, replace HDD and re-install system
based on judging HDD failure.
E602 -1124
-00
Title
Hard disk failure
Description
/APL_MEAP is abnormal
of detection
Measures
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
2. If not recovery, replace HDD and re-install system
based on judging HDD failure.
E602 -1125
-00
Title
Hard disk failure
Description
/APL_MEAP is abnormal
of detection
Measures
It is very likely that document data such as Inbox on the
HDD are damaged.
1. Input applicable CHK-TYPE into a partition; and
execute HDD-CHECK (requires several minutes to
some dozens of minutes); and then power cycle
2. If not recovery, input applicable CHK-TYPE into a
partition; and execute HDD-CLEAR; and then power
cycle
(in the case of BOOTDEV, BOOTDEV2, APL_SEND,
execute re-format / reinstallation with SST)
3. If still not recovery, replace HDD and re-install system
based on judging HDD failure.
E602 -1200
-00
Title
Hard disk failure
Description
/APL_SEND is abnormal
of detection
Measures
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
3. If still not recovery, replace HDD and re-install system
based on judging HDD failure.
Description
E
Detailed
Occurance
Items
code
code
area
E602 -1201
-00
Title
Hard disk failure
Description
/APL_SEND is abnormal
of detection
Measures
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
3. If still not recovery, replace HDD and re-install system
E602 -1202
-00
Title
Hard disk failure
Description
/APL_SEND is abnormal
of detection
Measures
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
3. If still not recovery, replace HDD and re-install system
E602 -1203
-00
Title
Hard disk failure
Description
/APL_SEND is abnormal
of detection
Measures
Recovery of boot partition should be executed with SST
in safe mode
1. Execute HDD-CHECK (requires some dozens of
2. If not recovery, shift to a download mode; and use
E602 -1204
-00
Title
Hard disk failure
Description
/APL_SEND is abnormal
of detection
Measures
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
3. If still not recovery, replace HDD and re-install system
Description
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
based on judging HDD failure.
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
based on judging HDD failure.
minutes) with CHK-TYPE=0; and then power cycle
SST to execute full-format and to re-install system
(SYSTEM, LANGUAGE, RUI); and then power cycle of
main power (Power OFF/ON)
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
based on judging HDD failure.
3
3-127

Hide quick links: