Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 621

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

COPIER> OPTION> USER
CTM-S06
Set of password delete from export file
Lv.2 Details
To set to delete password for file transmission address from export
file.
With the setting to delete password, the password of file transmission
target is deleted at the time of export of address book data from
remote UI.
Use case
• Upon user's request
• When avoiding information leak
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Password is retained, 1: Password is deleted.
Default value
0
FREG-SW
Dis/hide of MEAP counter free rgst area
Lv.2 Details
To set whether to display or hide the free register area of MEAP
counter for SEND
Use case
At trouble analysis
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
• Do not use this at the normal service.
• Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
0
Supplement/memo
Individual count-up (counter advance) of MEAP application is
available in the free register area of MEAP counter.
IFAX-SZL
Setting of IFAX send size limit
Lv.2 Details
To set for restricting data size at the time of IFAX transmission that
does not go through the server.
With the setting to restrict the data size, there will be #830 error in
the case of sending data that exceeds the upper limit value.
In the case that the data goes through the server, the size of
transmission data is always restricted.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Limited, 1: Not limited (Restriction applies when data goes through
the server.)
Default value
1
Related user mode
Function Settings > Send > E-Mail/I-Fax Settings > Maximum Data
Size for Sending
Supplement/memo
Specify the upper limit value for transmission data size in user mode.
COPIER> OPTION> USER
IFAX-PGD
Set page split TX at IFAX Simple mode TX
Lv.2 Details
To set to enable/disable split-data transmission on a page basis in
the case that the transmission size in IFAX Simple mode exceeds
the upper limit value.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
In the case to enable split-data transmission, be sure to get approval
from the user by explaining the following:
• No guarantee for page order on the reception side
• There is a possibility of interruption of other received jobs
between pages
Display/adj/set range
0 to 1
0: Disabled, 1: Enabled
Default value
0
Related service mode
COPIER> OPTION> CLEANING> W-CLN-P
Related user mode
Function Settings > Send > E-Mail/I-Fax Settings > Maximum Data
Size for Sending
Supplement/memo
Specify the upper limit value for transmission data size in user mode.
MEAPSAFE
Setting of MEAP safe mode
Lv.2 Details
To set safe mode for MEAP platform.
MPSF is displayed on the Control Panel in safe mode.
In safe mode, MEAP application is stopped while just the system
application, which starts with initial state, is activated. This mode
enables obtaining log for cause analysis of MEAP failure.
Use case
Perform system recovery processing when MEAP platform fails to
be activated due to resource confliction between MEAP applications,
service registration or use order
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Normal mode, 1: Safe mode
Default value
0
TRAY-FLL
Set of target tray for tray full notice
Lv.2 Details
To set the tray which is the target of an output tray full notification.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: All trays to which paper can be output, 1: All trays which are
specified as the dedicated trays
Default value
0