Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 164

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E602 -FF10
-00
Title
Description
of detection
Measures
E602 -FF11
-00
Title
Description
of detection
Measures
E602 -FF12
-00
Title
Description
3
of detection
Measures
E602 -FF13
-00
Title
Description
of detection
Measures
3-138
Description
Hard disk failure
Abnormality of unidentified partition
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
2. If not recovery, replace HDD and re-install system
based on judging HDD failure.
Hard disk failure
Abnormality of unidentified partition
This is an error that usually does not occur at Read/Write
level.
1. Check a cable or power supply connector
2. If not recovery, replace HDD and re-install system
based on judging HDD failure.
Hard disk failure
Abnormality of unidentified partition
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
2. If not recovery, replace HDD and re-install system
based on judging HDD failure.
Hard disk failure
Abnormality of unidentified partition
It is very likely that document data such as Inbox on the
HDD are damaged.
1. Input applicable CHK-TYPE into a partition; and
execute HDD-CHECK (requires several minutes to
some dozens of minutes); and then power cycle
2. If not recovery, input applicable CHK-TYPE into a
partition; and execute HDD-CLEAR; and then power
cycle
(in the case of BOOTDEV, BOOTDEV2, APL_SEND,
execute re-format / reinstallation with SST)
3. If still not recovery, replace HDD and re-install system
based on judging HDD failure.
E
Detailed
Occurance
Items
code
code
area
E602 -FF14
-00
Title
Hard disk failure
Description
Abnormality of unidentified partition
of detection
Measures
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
2. If not recovery, replace HDD and re-install system
E602 -FF21
-00
Title
Hard disk failure
Description
Abnormality of unidentified partition
of detection
Measures
This is an error that usually does not occur at Read/Write
level.
1. Check a cable or power supply connector
2. If not recovery, replace HDD and re-install system
E602 -FF22
-00
Title
Hard disk failure
Description
Abnormality of unidentified partition
of detection
Measures
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
2. If not recovery, replace HDD and re-install system
E602 -FF23
-00
Title
Hard disk failure
Description
Abnormality of unidentified partition
of detection
Measures
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
2. If not recovery, replace HDD and re-install system
Description
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
based on judging HDD failure.
based on judging HDD failure.
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
based on judging HDD failure.
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
based on judging HDD failure.