COPIER> DISPLAY> HT-C
DLTA-A-K
Dis of ARCDAT screen A Bk-density differ
Lv.2 Details
To display the difference between the Bk-patch target value and the
current value of screen A in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen A: High screen ruling screen
DLTA-B-Y
Dis of ARCDAT screen B Y-density differ
Lv.2 Details
To display the difference between the Y-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen B: Low screen ruling screen
DLTA-B-M
Dis of ARCDAT screen B M-density differ
5
Lv.2 Details
To display the difference between the M-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen B: Low screen ruling screen
5-88
COPIER> DISPLAY> HT-C
DLTA-B-C
Dis of ARCDAT screen B C-density differ
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen B: Low screen ruling screen
DLTA-B-K
Dis of ARCDAT screen B Bk-density differ
Lv.2 Details
To display the difference between the Bk-patch target value and the
current value of screen B in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen B: Low screen ruling screen
DLTA-C-Y
Dis of ARCDAT screen C Y-density differ
Lv.2 Details
To display the difference between the Y-patch target value and the
current value of screen C in ARCDAT control.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset the target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen C: Copier image processing screen