COPIER> ADJUST> FEED-ADJ
LP-FEED2
Casstt pre-rgst arch amount:Heavy/Transp
Lv.1 Details
To adjust the arch amount before registration when feeding heavy
paper/transparency from the cassette.
As the value is incremented by 1, the pre-registration arch amount
changes by 0.1 mm.
+: Increase
-: Decrease
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-50 to 50
Unit
0.1 mm
Default value
0
LP-MULT1
MP Tray pre-rgst arch amount: Plain
Lv.1 Details
To adjust the arch amount before registration when feeding plain
paper from the Multi-purpose Tray.
As the value is incremented by 1, the pre-registration arch amount
changes by 0.1 mm.
+: Increase
-: Decrease
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-50 to 50
Unit
0.1 mm
Default value
0
LP-MULT2
MP Tray pre-rgst arch amount:Heavy/Trans
Lv.1 Details
To adjust the arch amount before registration when feeding heavy
paper/transparency from the Multi-purpose Tray.
5
As the value is incremented by 1, the pre-registration arch amount
changes 0.1 mm.
+: Increase
-: Decrease
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-50 to 50
Unit
0.1 mm
Default value
0
5-244
COPIER> ADJUST> FEED-ADJ
LP-DUP1
Duplex pre-rgst arch amount: Plain
Lv.1 Details
To adjust the arch amount before registration when feeding plain
paper in duplex mode.
As the value is incremented by 1, the pre-registration arch amount
changes by 0.1 mm.
+: Increase
-: Decrease
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-50 to 50
Unit
0.1 mm
Default value
0
LP-DUP2
Duplex pre-rgst arch amount:Hvy/Transp
Lv.1 Details
To adjust the arch amount before registration when feeding heavy
paper/transparency in duplex mode.
As the value is incremented by 1, the pre-registration arch amount
changes by 0.1 mm.
+: Increase
-: Decrease
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-50 to 50
Unit
0.1 mm
Default value
0