Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 65

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E020 -0334
-05
Title
Initial installation patch (C) density upper limit error
Description
When executing developing assembly initial installation
of detection
mode (COPIER> FUNCTION> INSTALL> INISET-C), the
ATR patch output (SigD) is more than 970.
Measures
• When the value of COPIER> DISPLAY> DENS>
P-LED-DA is large (153(D) or more) and the value of
P-SENS-P is small, there is a high possibility that dirt is
applied to the patch sensor.
• This occurs only at a regular timing. When the value
of COPIER> DISPLAY> DENS> DENS-S-x is small
(2 digits), there is a high possibility that breaking
occurred.
1. Check whether the developing assembly and the drum
unit are properly installed.
2. Clean the patch sensor.
3. Check the connection between the patch sensor and
the DC controller interface PCB. (Connector, Shorting)
Sensor side: J7412, J8035 PCB side: J1242
4. Check open/close operation of the patch shutter.
5. Clean or replace the ITB.
6. Replace the patch sensor unit.
7. Replace the developing assembly.
Description
• Check whether the ITB belt is dirty or not. If it
is dirty, perform cleaning with the service mode
(COPIER> FUNCTION> CLEANING> TBLT-
CLN).
• If it is assumed that this error occurred due to
scratches on the ITB, replace the ITB.
E
Detailed
Occurance
Items
code
code
area
E020 -0336
-05
Title
Initial installation patch (C) sampling error
Description
When executing developing assembly initial installation
of detection
mode (COPIER> FUNCTION> INSTALL> INISET-C), the
variation before average patch P wave light intensity is
more than 100.
Measures
• When the value of COPIER> DISPLAY> DENS>P-
LED-DA is large (153(D) or more) and the value of
P-SENS-P is small, there is a high possibility that dirt is
applied to the patch sensor.
• This occurs only at a regular timing. When the value
of COPIER> DISPLAY> DENS> DENS-S-x is small
(2 digits), there is a high possibility that breaking
occurred.
1. Check whether the developing assembly and the drum
unit are properly installed.
2. Clean the patch sensor.
3. Check the connection between the patch sensor and
the DC controller interface PCB. (Connector, Shorting)
Sensor side: J7412, J8035 PCB side: J1242
4. Check open/close operation of the patch shutter.
5. Replace the patch sensor unit.
6. Replace the developing assembly.
E020 -0340
-05
Title
Initial installation toner density sensor (Bk) output upper
limit error
Description
When executing developing assembly initial installation
of detection
mode (COPIER> FUNCTION> INSTALL> INISET-K),
the output level does not reach 128 even when control
voltage of the toner density sensor became less than 55.
Measures
1. Check the connection between the toner density sensor
and the DC controller interface PCB. (Connector,
Shorting)
<Y> sensor side: J7133, J8028, J8087 PCB side:
J1240, J8085
<M> sensor side: J7134, J8029, J8088 PCB side:
J1240, J8085
<C> sensor side: J7135, J8030, J8089 PCB side:
J1240, J8086
<Bk> sensor side: J7146, J8015, J8117 PCB side:
J1240, J8086
2. Check whether disconnection or shorting of the toner
density sensor occurs or not.
3. Replace the developing assembly.
Description