MTF2-S2
MTF value 2 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S3
MTF value 3 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S4
MTF value 4 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
5
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S5
MTF value 5 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S6
MTF value 6 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
5-190
COPIER> ADJUST> CCD
MTF2-S7
MTF value 7 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S8
MTF value 8 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S9
MTF value 9 setting: vert scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 80
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
100DF2GB
Img Sensr GB color displace crrct VL:bck
Lv.2 Details
To correct the color displacement (G and B lines) in vertical scanning
direction due to the Scanner Unit (paper back).
When replacing the Reader Controller PCB/clearing RAM data, enter
the value of service label.
Use case
When replacing the Reader Controller PCB/clearing RAM data
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-256 to 256
Unit
0.001 line
Default value
0