Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 568

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

COPIER> OPTION> IMG-FIX
TMP-P2-2
Plain ppr2 ini rotn temp, print temp 2&3
Lv.2 Details
To adjust the initial ration temperature and print temperature 2 and 3
for "Plain 2".
Set a positive value when a fixing failure occurs, and set a negative
value when a separation failure or wrinkles occur.
When an image failure occurs, adjust appropriately.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, a separation failure, wrinkles or an image
failure occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When -3 or less is set, a fixing failure might occur.
Display/adj/set range
-7 to 2
-7: -35 deg C, -6: -30 deg C, -5: -25 deg C, -4: -20 deg C, -3: -15 deg
C, -2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
TMP-H1-1
Adj of heavy ppr 1 print temperature 1
Lv.2 Details
To adjust the print temperature 1 for "Heavy 1."
Set a positive value when a fixing failure occurs, and set a negative
value when a separation failure or wrinkles occur.
When an image failure occurs, adjust appropriately.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, a separation failure, wrinkles or an image
failure occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When -3 or less is set, a fixing failure might occur.
Display/adj/set range
-9 to 2
5
-9: -45 deg C, -8: -40 deg C, -7: -35 deg C, -6: -30 deg C, -5: -25 deg
C, -4: -20 deg C, -3: -15 deg C, -2: -10 deg C, -1: -5 deg C, 0: 0 deg C,
1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
5-340
COPIER> OPTION> IMG-FIX
TMP-H1-2
Heavy ppr1 ini rotn temp, print temp 2&3
Lv.2 Details
To adjust the initial ration temperature and print temperature 2 and 3
for "Heavy 1".
Set a positive value when a fixing failure occurs, and set a negative
value when a separation failure or wrinkles occur.
When an image failure occurs, adjust appropriately.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, a separation failure, wrinkles or an image
failure occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When -3 or less is set, a fixing failure might occur.
Display/adj/set range
-7 to 2
-7: -35 deg C, -6: -30 deg C, -5: -25 deg C, -4: -20 deg C, -3: -15 deg
C, -2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
TMP-H2-1
Adj of heavy ppr 2 print temperature 1
Lv.2 Details
To adjust the print temperature 1 for "Heavy 2".
Set a positive value when a fixing failure occurs.
In addition, use this mode when an image failure or deterioration of
gloss occurs.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, an image failure, or deterioration of gloss
occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-4 to 2
-4: -20 deg C, -3: -15 deg C, -2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1:
+5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
TMP-H2-2
Heavy ppr2 ini rotn temp, print temp 2&3
Lv.2 Details
To adjust the initial rotation temperature, print temperature 2 and 3
for "Heavy 2".
Set a positive value when a fixing failure occurs.
In addition, use this mode when an image failure or deterioration of
gloss occurs.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, an image failure, or deterioration of gloss
occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0

Hide quick links: