■ PRDC-1
COPIER> COUNTER> PRDC-1
PRM-WIRE
Primary Charging Wire parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
Supplement/memo
This is commonly used as operator maintenance parts counter.
PRM-GRID
Grid Plate parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PO-WIRE
Pre-transfer Charging Wire parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
5
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PRM-CLN
Primary Charge Wire Clean Pad prts cntr
Lv.1 Details
Primary Charging Wire Cleaning Pad 1, 2
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
5-458
COPIER> COUNTER> PRDC-1
PO-CLN
Pre-transfer Chg Wire Cln Pad prts cntr
Lv.1 Details
Pre-transfer Charging Wire Cleaning Pad 1, 2
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PRM-CLN2
Prmry Charge Wire Cleanr Pad2 prts cntr
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PO-CLN2
Pre-trn Chg Wire Clnr Pad2 parts cntr
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PO-UNIT
Pre-transfer Charging Ass'y parts cntr
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0