COPIER> DISPLAY> HV-STS
PRIACI-Y
Discharge current ctrl set current (Y)
Lv.2 Details
To display the AC current setting value to be Applied to the Y
Charging Roller At 1/1 speed derived from the latest discharge
current control.
Use case
When checking the current value (Y) for discharge current control
Display/adj/set range
0 to 5000
Unit
uA
Appropriate target value 1500 to 4000
Related service mode
COPIER> DISPLAY> HV-STS> PRIMACV-Y, PRIMACV-M,
PRIMACV-C, PRIACI-M, PRIACI-C, PRISMP-Y, PRISMP-M,
PRISMP-C
COPIER> FUNCTION> MISC-P> DISCHG
PRIACI-M
Discharge current ctrl set current (M)
Lv.2 Details
To display the AC current setting value to be Applied to the M
Charging Roller derived from the latest discharge current control.
Use case
When checking the current value (M) for discharge current control
Display/adj/set range
0 to 5000
Unit
uA
Appropriate target value 1500 to 4000
Related service mode
COPIER> DISPLAY> HV-STS> PRIMACV-Y, PRIMACV-M,
PRIMACV-C, PRIACI-Y, PRIACI-C, PRISMP-Y, PRISMP-M,
PRISMP-C
COPIER> FUNCTION> MISC-P> DISCHG
PRIACI-C
Discharge current ctrl set current (C)
Lv.2 Details
To display the AC current setting value to be Applied to the C
Charging Roller derived from the latest discharge current control
Use case
When checking the current value (C) for discharge current control
5
Display/adj/set range
0 to 5000
Unit
uA
Appropriate target value 1500 to 4000
Related service mode
COPIER> DISPLAY> HV-STS> PRIMACV-Y, PRIMACV-M,
PRIMACV-C, PRIACI-Y, PRIACI-M, PRISMP-Y, PRISMP-M,
PRISMP-C
COPIER> FUNCTION> MISC-P> DISCHG
5-64
COPIER> DISPLAY> HV-STS
PRISMP-Y
Discharge current ctrl sampling point(Y)
Lv.2 Details
To display the AC current value flown on the Y Charging Roller when
the certain voltage is Applied by the latest discharge current control.
AC current/current to be Applied At 1/1 speed is derived from 6
sampling results.
Use case
When checking the sampling results of discharge current control
Display/adj/set range
0 to 5000
Unit
1 uA
Appropriate target value 1000 to 4000
Related service mode
COPIER> DISPLAY> HV-STS> PRISMP-M, PRISMP-C,
PRIMACV-Y, PRIMACV-M, PRIMACV-C, PRIACI-Y, PRIACI-M,
PRIACI-C
COPIER> FUNCTION> MISC-P> DISCHG
PRISMP-M
Discharge current ctrl sampling point(M)
Lv.2 Details
To display the AC current value flown on the M Charging Roller when
the certain voltage is Applied by the latest discharge current control.
AC current/current to be Applied At 1/1 speed is derived from 6
sampling results.
Use case
When checking the sampling results of discharge current control
Display/adj/set range
0 to 5000
Unit
1 uA
Appropriate target value 1000 to 4000
Related service mode
COPIER> DISPLAY> HV-STS> PRISMP-Y, PRISMP-C, PRIMACV-Y,
PRIMACV-M, PRIMACV-C, PRIACI-Y, PRIACI-M, PRIACI-C
COPIER> FUNCTION> MISC-P> DISCHG
PRISMP-C
Discharge current ctrl sampling point(C)
Lv.2 Details
To display the AC current value flown on the C Charging Roller when
the certain voltage is Applied by the latest discharge current control.
AC current/current to be Applied At 1/1 speed is derived from 6
sampling results.
Use case
When checking the sampling results of discharge current control
Display/adj/set range
0 to 5000
Unit
1 uA
Appropriate target value 1000 to 4000
Related service mode
COPIER> DISPLAY> HV-STS> PRISMP-Y, PRISMP-M, PRIMACV-Y,
PRIMACV-M, PRIMACV-C, PRIACI-Y, PRIACI-M, PRIACI-C
COPIER> FUNCTION> MISC-P> DISCHG
T-5-6