Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 136

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E602 -0223
-00
Title
Description
of detection
Measures
E602 -0224
-00
Title
Description
of detection
Measures
3
E602 -0225
-00
Title
Description
of detection
Measures
E602 -0300
-00
Title
Description
of detection
Measures
3-110
Description
Hard disk failure
/IMG_MNG is abnormal
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
2. If not recovery, replace HDD and re-install system
based on judging HDD failure.
Hard disk failure
/IMG_MNG is abnormal
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
2. If not recovery, replace HDD and re-install system
based on judging HDD failure.
Hard disk failure
/IMG_MNG is abnormal
It is very likely that document data such as Inbox on the
HDD are damaged.
1. Input applicable CHK-TYPE into a partition; and
execute HDD-CHECK (requires several minutes to
some dozens of minutes); and then power cycle
2. If not recovery, input applicable CHK-TYPE into a
partition; and execute HDD-CLEAR; and then power
cycle
(in the case of BOOTDEV, BOOTDEV2, APL_SEND,
execute re-format / reinstallation with SST)
3. If still not recovery, replace HDD and re-install system
based on judging HDD failure.
Hard disk failure
/FSTCDEV is abnormal
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
3. If still not recovery, replace HDD and re-install system
based on judging HDD failure.
E
Detailed
Occurance
Items
code
code
area
E602 -0301
-00
Title
Hard disk failure
Description
/FSTCDEV is abnormal
of detection
Measures
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
3. If still not recovery, replace HDD and re-install system
E602 -0302
-00
Title
Hard disk failure
Description
/FSTCDEV is abnormal
of detection
Measures
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
3. If still not recovery, replace HDD and re-install system
E602 -0303
-00
Title
Hard disk failure
Description
/FSTCDEV is abnormal
of detection
Measures
1. Input applicable CHK-TYPE into a partition; and
2. If not recovery, input applicable CHK-TYPE into a
E602 -0304
-00
Title
Hard disk failure
Description
/FSTCDEV is abnormal
of detection
Measures
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
3. If still not recovery, replace HDD and re-install system
E602 -0305
-00
Title
Hard disk failure
Description
/FSTCDEV is abnormal
of detection
Measures
1. Input applicable CHK-TYPE into a partition; and
2. If not recovery, replace HDD and re-install system
Description
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
based on judging HDD failure.
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
based on judging HDD failure.
execute HDD-CHECK (requires several minutes to
some dozens of minutes); and then power cycle
partition; and execute HDD-CLEAR; and then power
cycle
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
based on judging HDD failure.
execute HDD-CLEAR; and then power cycle
based on judging HDD failure.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents