COPIER> OPTION> CLEANING
OHP-PTH
Set of ITB clean transp threshold value
Lv.2 Details
When a large number of transparencies is fed, surface active agent
which coats the surface of an transparency adheres to the ITB, and
consequently the transfer efficiency is lowered, causing an image
failure. After feeding a certain number of transparencies, a patch
is formed on the ITB, and the ITB Cleaning Blade scrapes it off
together with surface active agent.
This setting is used to set the threshold value for the number of fed
transparency which is the condition to execute ITB cleaning.
Use case
When an image failure occurs due to lowering of the transfer
efficiency
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 100
0: Not executed
Unit
Number of sheets
Default value
15
Related service mode
COPIER> FUNCTION> CLEANING> TBLT-CLN
W-CLN-PH
ON/OFF of Charging Wire auto cleaning
Lv.2 Details
To set ON/OFF of automatic cleaning of the Primary Charging Wire
and Pre-transfer Charging Wire.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
Related service mode
COPIER> OPTION> CLEANING> W-CLN-P, W-CLN-T
5
5-360
■ ENV-SET
ENVP-INT
Lv.1 Details
Use case
Adj/set/operate method 1) Enter the setting value, and then press OK key.
Display/adj/set range
Unit
Default value
Related service mode
DRY-CISU
Lv.1 Details
Use case
Display/adj/set range
T-5-68
COPIER> OPTION> ENV-SET
Temp, humid &Fix Belt temp log get cycle
To set the cycle to obtain log of the humidity inside the machine and
the surface temperature of the Fixing Belt.
As the value is incremented by 1, the cycle is increased by 1 minute.
Obtained log can be displayed by selecting the following: COPIER >
DISPLAY > ENVRNT
At trouble analysis
2) Turn OFF/ON the main power switch.
0 to 480
1 minute
60
COPIER> DISPLAY> ENVRNT
ON/OFF of condensation prevention mode
To set ON/OFF of condensation mode.
When droplets are appeared on the Scanner Unit due to
condensation and image failure or E225 occurs, set "1: ON".
By selecting 1, the Scanner Unit (paper front) stops the fan for
15 seconds and the Scanner Unit (paper back) lights LED for 30
seconds from the next startup.
When droplets are appeared on the Scanner Unit due to
condensation and image failure or E225 occurs
0 to 1
0: OFF (Normal mode), 1: ON (Anti-condensation mode)