Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 566

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

COPIER> OPTION> DSPLY-SW
CNTCNFSW
ON/OFF of Counter Check screen display
Lv.1 Details
To set whether to display the Counter Check screen.
When 1 is set, the Counter Check screen can be displayed. The
setting value automatically returns to 0 (OFF) when the screen is
closed.
Use case
When checking the counter at servicing
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
5
5-338
■ IMG-FIX
FX-WUT
Lv.2 Details
Use case
T-5-60
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
Unit
Default value
TMP-ST1
Lv.1 Details
Use case
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Display/adj/set range
Unit
Default value
Supplement/memo
COPIER> OPTION> IMG-FIX
Set of Fixing Assembly warm-up time
To set the warm-up time of the Fixing Assembly, which is performed
first time for the day.
Use "0: Initial value" in the normal operation.
Extend the time as needed when a fixing failure occurs first time for
the day.
As the value is incremented by 1, the time is increased by 60
seconds.
• When a fixing failure occurs first time for the day
• In the environment of 15 deg C or lower
• When using media out of the specifications
0 to 3
0: Initial value, 1: Initial value + 60 seconds, 2: Initial value + 120
seconds, 3: Initial value + 180 seconds
60 seconds
0
Adjustment of standby 1 temperature
To adjust the fixing start target temperature, fixing recovery target
temperature and standby 1 fixing control temperature.
Set a positive value when a fixing failure occurs first time for the day,
and set a negative value when a control temperature cooling wait
time is shorten. (Note the fixing failure.)
• When a fixing failure occurs first time for the day
• When a control temperature cooling wait time is shorten
When -3 or less is set, a fixing failure might occur.
-7 to 2 (Although -7 or -6 is entered, the value is automatically set to
-5.)
-7 to -5: -25 deg C, -4: -20 deg C, -3: -15 deg C, -2: -10 deg C, -1: -5
deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
5 deg C
0
Standby 1: within 5 minutes since the completion of startup/recovery