COPIER> ADJUST> HV-TR
1TR-TK12
Adj Bk Pry Trns ATVC tgt crrnt:1/2 speed
Lv.2 Details
To adjust the offset of the target current value for pure black upon
primary transfer ATVC control at 1/2 speed.
Increase the value when spots, mottled image, or image failure due
to insufficient transfer current occurs.
Decrease the value when image fogging due to transfer memory or
drum memory due to strong transfer current occurs.
Use case
When an image failure due to inappropriate primary transfer current
setting occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-10 to 10
Default value
0
1TR-TGY3
Adj Y Pry Trns ATVC tgt crrnt:1/3 speed
Lv.2 Details
To adjust the offset of the target current value for Y upon primary
transfer ATVC control at 1/3 speed.
Increase the value when spots, mottled image, or image failure due
to insufficient transfer current occurs.
Decrease the value when image fogging due to transfer memory or
drum memory due to strong transfer current occurs.
Use case
When an image failure due to inappropriate primary transfer current
setting occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-10 to 10
5
Default value
0
1TR-TGM3
Adj M Pry Trns ATVC tgt crrnt:1/3 speed
Lv.2 Details
To adjust the offset of the target current value for M upon primary
transfer ATVC control at 1/3 speed.
Increase the value when spots, mottled image, or image failure due
to insufficient transfer current occurs.
Decrease the value when image fogging due to transfer memory or
drum memory due to strong transfer current occurs.
Use case
When an image failure due to inappropriate primary transfer current
setting occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-10 to 10
Default value
0
5-240
COPIER> ADJUST> HV-TR
1TR-TGC3
Adj C Pry Trns ATVC tgt crrnt:1/3 speed
Lv.2 Details
To adjust the offset of the target current value for C upon primary
transfer ATVC control at 1/3 speed.
Increase the value when spots, mottled image, or image failure due
to insufficient transfer current occurs.
Decrease the value when image fogging due to transfer memory or
drum memory due to strong transfer current occurs.
Use case
When an image failure due to inappropriate primary transfer current
setting occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-10 to 10
Default value
0
1TR-TK13
Adj Bk Pry Trns ATVC tgt crrnt:1/3 speed
Lv.2 Details
To adjust the offset of the target current value for pure black upon
primary transfer ATVC control at 1/3 speed.
Increase the value when spots, mottled image, or image failure due
to insufficient transfer current occurs.
Decrease the value when image fogging due to transfer memory or
drum memory due to strong transfer current occurs.
Use case
When an image failure due to inappropriate primary transfer current
setting occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-10 to 10
Default value
0
1TR-TK42
Adj clr Bk Pry Trn ATVC tgt crrnt:1/2SPD
Lv.2 Details
To adjust the offset of the target current value for Bk (color) upon
primary transfer ATVC control at 1/2 speed.
As the value is incremented by 1, the offset is increased by 2 micro A.
Increase the value if spots (white spots), leopard pattern image
occurs.
Decrease the value if white dots occur.
Decrease the value if mottled image due to paper surface nature
occurs when paper type is heavy paper 1/2.
Use case
When an image failure due to inappropriate primary transfer current
setting occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-10 to 10
Unit
2 micro A
Default value
0