Detailed
Occurance
Items
code
code
area
E602 -0802
-00
Title
Description
of detection
Measures
E602 -0803
-00
Title
Description
of detection
Measures
E602 -0804
-00
Title
3
Description
of detection
Measures
E602 -0805
-00
Title
Description
of detection
Measures
E602 -0810
-00
Title
Description
of detection
Measures
3-120
Description
Hard disk failure
/TMP_PSS is abnormal
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
3. If still not recovery, replace HDD and re-install system
based on judging HDD failure.
Hard disk failure
/TMP_PSS is abnormal
1. Input applicable CHK-TYPE into a partition; and
execute HDD-CHECK (requires several minutes to
some dozens of minutes); and then power cycle
2. If not recovery, input applicable CHK-TYPE into a
partition; and execute HDD-CLEAR; and then power
cycle
Hard disk failure
/TMP_PSS is abnormal
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
3. If still not recovery, replace HDD and re-install system
based on judging HDD failure.
Hard disk failure
/TMP_PSS is abnormal
1. Input applicable CHK-TYPE into a partition; and
execute HDD-CLEAR; and then power cycle
2. If not recovery, replace HDD and re-install system
based on judging HDD failure.
Hard disk failure
/TMP_PSS is abnormal
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
2. If not recovery, replace HDD and re-install system
based on judging HDD failure.
E
Detailed
Occurance
Items
code
code
area
E602 -0811
-00
Title
Hard disk failure
Description
/TMP_PSS is abnormal
of detection
Measures
This is an error that usually does not occur at Read/Write
level.
1. Check a cable or power supply connector
2. If not recovery, replace HDD and re-install system
E602 -0812
-00
Title
Hard disk failure
Description
/TMP_PSS is abnormal
of detection
Measures
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
2. If not recovery, replace HDD and re-install system
E602 -0813
-00
Title
Hard disk failure
Description
/TMP_PSS is abnormal
of detection
Measures
It is very likely that document data such as Inbox on the
HDD are damaged.
1. Input applicable CHK-TYPE into a partition; and
2. If not recovery, input applicable CHK-TYPE into a
3. If still not recovery, replace HDD and re-install system
E602 -0814
-00
Title
Hard disk failure
Description
/TMP_PSS is abnormal
of detection
Measures
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
2. If not recovery, replace HDD and re-install system
Description
based on judging HDD failure.
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
based on judging HDD failure.
execute HDD-CHECK (requires several minutes to
some dozens of minutes); and then power cycle
partition; and execute HDD-CLEAR; and then power
cycle
(in the case of BOOTDEV, BOOTDEV2, APL_SEND,
execute re-format / reinstallation with SST)
based on judging HDD failure.
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
based on judging HDD failure.