Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 573

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

COPIER> OPTION> IMG-FIX
TMP-C6
[Not used]
NIP-DWN1
Adj of pressure amount: Plain paper 2
Lv.2 Details
To adjust the pressure amount of the Pressure Belt when feeding
"Plain 2."
Use 0 (initial value) in the normal operation.
As the value is smaller, the pressure amount is decreased.
Use case
When paper edge scratches the Pressure Belt
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
FCOT, wrinkles, and fixing deterioration at the edge might occur.
Display/adj/set range
-6 to 0
-6: 892 pulses, -5: 792 pulses, -4: 692 pulses, -3: 592 pulses, -2: 492
pulses, -1: 392 pulses, 0: 0 pulse
Unit
100 pulses
Default value
0
FX-ERRSW
ON/OFF of Fixing Belt Unit life judgment
Lv.2 Details
To set whether to judge the life of the Fixing Belt Unit using the
number of fed sheets.
The number of fed sheets is counted by COPIER> COUNTER>
DRBL-1> FX-BLT-U.
When 1 is set, FX-U-ERR (error display) is enabled.
Use case
When enabling the judgment of the Fixing Belt Unit life
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Related service mode
COPIER> COUNTER> DRBL-1> FX-BLT-U
COPIER> OPTION> IMG-FIX> FX-U-ERR
FX-U-ERR
Set Fix Belt Unit life error thresholdVL
Lv.2 Details
To set the threshold value for the number of fed sheets which an
error indicating that the Fixing Belt Unit reaches its life is displayed
when the life of the Fixing Belt Unit is judged by the number of fed
sheets.
The number of fed sheets is counted by COPIER> COUNTER>
DRBL-1> FX-BLT-U.
When FX-ERRSW is 1, this setting is enabled.
Use case
When enabling the judgment of the Fixing Belt Unit life
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
1 to 4
1: 300K, 2: 400K, 3: 500K, 4: 600K
Default value
2
Related service mode
COPIER> COUNTER> DRBL-1> FX-BLT-U
COPIER> OPTION> IMG-FIX> FX-ERRSW
COPIER> OPTION> FNC-SW> FXWRNLVL
COPIER> OPTION> DSPLY-SW> FXMSG-SW, FXMSGSW2
COPIER> OPTION> IMG-FIX
TMP-C1B
Adj coated ppr 1B print fix ctrl temp
Lv.2 Details
To adjust the initial rotation temperature and print temperature 1 to 3
for "Coated 1" which paper weight is 129 to 150g/m2 (default).
Set a negative value when wrinkles occur, and set a positive value
when a fixing failure occurs.
In addition, use this mode when an image failure or deterioration of
gloss occurs.
Use 0 (initial value) in the normal operation.
Use case
When wrinkles, a fixing failure, an image failure, or deterioration of
gloss occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
TMP-C1C
Adj coated ppr 1C print fix ctrl temp
Lv.2 Details
To adjust the initial rotation temperature and print temperature 1 to 3
for "Coated 1" which paper weight is customized to 151 to 180g/m2.
Set a negative value when wrinkles occur, and set a positive value
when a fixing failure occurs.
In addition, use this mode when an image failure or deterioration of
gloss occurs.
Use 0 (initial value) in the normal operation.
Use case
When wrinkles, a fixing failure, an image failure, or deterioration of
gloss occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
TMP-C5B
Adj coated ppr 5B print fix ctrl temp
Lv.2 Details
To adjust the initial rotation temperature and print temperature 1 to 3
for "Coated 5" which paper weight is 129 to 150g/m2 (default).
Set a positive value when a fixing failure occurs.
In addition, use this mode when an image failure or deterioration of
gloss occurs.
Use 0 (initial value) in the normal operation.
Use case
When a fixing failure, an image failure, or deterioration of gloss
occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
5
5-345