Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 74

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E023 -0102
-05
Title
Description
of detection
Measures
E023 -0201
-05
Title
3
Description
of detection
Measures
3-48
Description
Developing stirring motor (Y) error
Lock signal of Developing stirring motor (Y) (M26)cannot
be detected for the specified period of time after first
detection
• Connector disconnected, breaking (shorting)
• Failure of the developing assembly (Sleeve
overloaded)
• Failure of the DC controller interface PCB (Fuse (FU7
burns))
• Contact failure of the drawer connector
• Failure of the developing stirring motor
1. Check the connection between the developing stirring
motor (Y) and the DC controller interface PCB (UN2).
(Connection of the connector, Breaking (shorting))
Motor side: J7158, J8038 PCB side: J1246
2. Replace the developing assembly (Y).
3. Replace the DC controller interface PCB.
4. Check the contact of the drawer connector (J8031).
5. Replace the developing stirring motor (Y).
Developing stirring motor (M) error
The lock signal of the developing stirring motor (M) (M28)
cannot be detected within a specified period.
• Connector disconnected, breaking (shorting)
• Failure of the developing assembly (Sleeve
overloaded)
• Failure of the DC controller interface PCB (Fuse (FU7
burns))
• Contact failure of the drawer connector
• Failure of the developing stirring motor
1. Check the connection between the developing stirring
motor (M) and the DC controller interface PCB (UN2).
(Connection of the connector, Breaking (shorting))
Motor side: J7156, J8038 PCB side: J1246
2. Replace the developing assembly (Y).
3. Replace the DC controller interface PCB.
4. Check the contact of the drawer connector (J8031).
5. Replace the developing stirring motor (M).
E
Detailed
Occurance
Items
code
code
area
E023 -0202
-05
Title
Developing stirring motor (M) error
Description
Lock signal of Developing stirring motor (M) (M28) cannot
of detection
be detected for the specified period of time after first
detection
• Connector disconnected, breaking (shorting)
• Failure of the developing assembly (Sleeve
• Failure of the DC controller interface PCB (Fuse (FU7
• Contact failure of the drawer connector
• Failure of the developing stirring motor
Measures
1. Check the connection between the developing stirring
2. Replace the developing assembly (Y).
3. Replace the DC controller interface PCB.
4. Check the contact of the drawer connector (J8031).
5. Replace the developing stirring motor (M).
E023 -0301
-05
Title
Developing stirring motor (C) error
Description
The lock signal of the developing stirring motor (C) (M27)
of detection
cannot be detected within a specified period.
• Connector disconnected, breaking (shorting)
• Failure of the developing assembly (Sleeve
• Failure of the DC controller interface PCB (Fuse (FU7
• Contact failure of the drawer connector
• Failure of the developing stirring motor
Measures
1. Check the connection between the developing stirring
2. Replace the developing assembly (C).
3. Replace the DC controller interface PCB.
4. Check the contact of the drawer connector (J8031).
5. Replace the developing stirring motor (C).
Description
overloaded)
burns))
motor (M) and the DC controller interface PCB (UN2).
(Connection of the connector, Breaking (shorting))
Motor side: J7156, J8038 PCB side: J1246
overloaded)
burns))
motor (C) and the DC controller interface PCB (UN2).
(Connection of the connector, Breaking (shorting))
Motor side: J7157, J8038 PCB side: J1246

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents