Canon imageRUNNER ADVANCE 9070 PRO series Service Manual Digest page 161

Hide thumbs Also See for imageRUNNER ADVANCE 9070 PRO series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E602 -1600
-00
Title
Hard disk failure
Description
/APL_CDS is abnormal
of detection
Measures
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
3. If still not recovery, replace HDD and re-install system
based on judging HDD failure.
E602 -1601
-00
Title
Hard disk failure
Description
/APL_CDS is abnormal
of detection
Measures
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
3. If still not recovery, replace HDD and re-install system
based on judging HDD failure.
E602 -1602
-00
Title
Hard disk failure
Description
/APL_CDS is abnormal
of detection
Measures
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
3. If still not recovery, replace HDD and re-install system
based on judging HDD failure.
E602 -1603
-00
Title
Hard disk failure
Description
/APL_CDS is abnormal
of detection
Measures
1. Input applicable CHK-TYPE into a partition; and
execute HDD-CHECK (requires several minutes to
some dozens of minutes); and then power cycle
2. If not recovery, input applicable CHK-TYPE into a
partition; and execute HDD-CLEAR; and then power
cycle
Description
E
Detailed
Occurance
Items
code
code
area
E602 -1604
-00
Title
Hard disk failure
Description
/APL_CDS is abnormal
of detection
Measures
1. Check a cable or power supply connector
2. If not recovery, Boot-up in safe mode, and use SST to
3. If still not recovery, replace HDD and re-install system
E602 -1605
-00
Title
Hard disk failure
Description
/APL_CDS is abnormal
of detection
Measures
1. Input applicable CHK-TYPE into a partition; and
2. If not recovery, replace HDD and re-install system
E602 -1610
-00
Title
Hard disk failure
Description
/APL_CDS is abnormal
of detection
Measures
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
2. If not recovery, replace HDD and re-install system
E602 -1611
-00
Title
Hard disk failure
Description
/APL_CDS is abnormal
of detection
Measures
This is an error that usually does not occur at Read/Write
level.
1. Check a cable or power supply connector
2. If not recovery, replace HDD and re-install system
E602 -1612
-00
Title
Hard disk failure
Description
/APL_CDS is abnormal
of detection
Measures
This is an error due to data error or software bug.
1. Boot-up in safe mode, and use SST to execute full-
2. If not recovery, replace HDD and re-install system
Description
execute full-format and to re-install system (SYSTEM,
LANGUAGE, RUI); and then power cycle of main
power (Power OFF/ON)
based on judging HDD failure.
execute HDD-CLEAR; and then power cycle
based on judging HDD failure.
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
based on judging HDD failure.
based on judging HDD failure.
format and to re-install system (SYSTEM, LANGUAGE,
RUI); and then power cycle of main power (Power
OFF/ON)
based on judging HDD failure.