COPIER> DISPLAY> HT-C
SUM-C-M3
ARCDAT scrnC M-clr ctrl differ (1/3 SPD)
Lv.2 Details
To display M-patch control difference of screen C in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset target
value). If not corrected, check Patch Sensor or replace the developer.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen C: Copier image processing screen
SUM-C-C3
ARCDAT scrnC C-clr ctrl differ (1/3 SPD)
Lv.2 Details
To display C-patch control difference of screen C in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset target
value). If not corrected, check Patch Sensor or replace the developer.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen C: Copier image processing screen
SUM-C-K3
ARCDAT scrnC Bk-clr ctrl differ(1/3 SPD)
Lv.2 Details
To display Bk-patch control difference of screen C in ARCDAT control
at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset target
value). If not corrected, check Patch Sensor or replace the developer.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen C: Copier image processing screen
COPIER> DISPLAY> HT-C
DLT-A-Y3
ARCDAT scrn A Y-density differ (1/3 SPD)
Lv.2 Details
To display the difference between the Y-patch target value and the
current value of screen A in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset target
value). If not corrected, check Patch Sensor and replace the
developer.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen A: High screen ruling screen
DLT-A-M3
ARCDAT scrn A M-density differ (1/3 SPD)
Lv.2 Details
To display the difference between the M-patch target value and the
current value of screen A in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset target
value). If not corrected, check Patch Sensor and replace the
developer.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0
Supplement/memo
Screen A: High screen ruling screen
DLT-A-C3
ARCDAT scrn A C-density differ (1/3 SPD)
Lv.2 Details
To display the difference between the C-patch target value and the
current value of screen A in ARCDAT control at 1/3 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute auto gradation adjustment (reset target
value). If not corrected, check Patch Sensor and replace the
developer.
Use case
When hue variation occurs
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-1023 to 1023
Default value
0